{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D53632","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D53632","canonicalUrl":"https://aoctrl.com/schneider/A9D53632","factsUrl":"https://aoctrl.com/api/mcp/products/A9D53632","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iDPN Vigi RCBO, 1P+N, 32 A, C-curve, 30 mA earth leakage, 6 kA breaking capacity, clip-on DIN rail.","salesMarkdown":"The Schneider Electric A9D53632 is an Acti9 iDPN Vigi residual-current circuit breaker (RCBO) — one module wide, combining overcurrent and earth-leakage protection in a single 1P+N package. Rated 32 A with a C-curve magnetic trip (5–10 × In) and 30 mA earth-leakage sensitivity, it's sized for final subcircuits in residential or light-commercial distribution boards where you need both short-circuit and personnel protection without stacking separate devices. The 6000 A Icn breaking capacity at 230–240 V AC (EN/IEC 61009-2-1) covers the vast majority of domestic and small commercial service entrances — it safely interrupts a fault up to that level without welding or exploding. The 30 mA earth-leakage threshold is the standard for personal shock protection; it will catch a live-to-ground fault through a person before ventricular fibrillation current is reached. Thermal-magnetic trip technology gives you a bimetal strip for overload (slow, time-inverse) and a solenoid for short-circuit (instantaneous above the magnetic threshold). That's the workhorse mechanism for this class — no electronics to fail, no auxiliary power needed. ## Panel integration Clips onto standard DIN rail (EN 60715) — 36 mm wide, 85 mm tall, 73 mm deep. The single-pole + neutral layout puts the neutral on the left; the 9 mm connection pitch between phase and neutral matches the Acti9 busbar system. Terminals accept 1–16 mm² rigid or 1–10 mm² flexible, with a 15 mm strip length and 2 N·m tightening torque.","metaTitle":"Schneider A9D53632 Acti9 iDPN Vigi 32A C-Curve 30mA RCBO","metaDescription":"Schneider Electric A9D53632 Acti9 iDPN Vigi RCBO, 32A rated, C-curve, 30mA earth leakage, 6kA breaking capacity. Active production, sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iDPN Vigi","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"6000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"iDPN N Vigi","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"32 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm for top or bottom connection","Connections - terminals":"Single terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"100 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50 Hz","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"230...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/34452df7c70f9683bf4ce7c18a34c555.pdf","sourceUrl":"https://www.se.com/be/en/product/A9D53632/residual-current-breaker-with-overcur-prot-rcbo-acti9-idpn-n-vigi-1p+n-32a-c-curve-6000a-asi-type-100ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D53632/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9D53632?","answer":"We source the A9D53632 to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit a request and we'll get you a firm number with no runaround."},{"question":"What is the breaking capacity of A9D53632?","answer":"The A9D53632 has a 6000 A Icn breaking capacity at 230–240 V AC, 50 Hz, conforming to EN/IEC 61009-2-1. That's the standard rating for most residential and light-commercial distribution boards."},{"question":"What does the C-curve mean on this RCBO?","answer":"The C-curve means the magnetic trip operates at 5 to 10 times the rated current (5–10 × In). For a 32 A device, that's 160–320 A instantaneous trip — it holds through motor start-up and transformer inrush but still clears a hard short fast."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D53632","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D53632 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}