{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D54613","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D54613","canonicalUrl":"https://aoctrl.com/schneider/A9D54613","factsUrl":"https://aoctrl.com/api/mcp/products/A9D54613","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iDPN Vigi, RCBO, 1P+N, 13 A, B-curve, 30 mA RCD, 4.5 kA breaking capacity, DIN rail.","salesMarkdown":"The Schneider Electric A9D54613 is an Acti9 iDPN Vigi combined residual current circuit breaker with overcurrent protection (RCBO) — a single-module device that packs a 13 A thermal-magnetic MCB and a 30 mA earth-leakage trip into one 36 mm-wide DIN-rail housing. It is a 1P+N unit, meaning it switches the live conductor and monitors the neutral, with the neutral on the left side of the terminal layout. The B-curve characteristic (magnetic trip between 3 and 5 times In) makes it a natural fit for residential or light commercial final circuits where the inrush from connected loads is modest — think lighting, socket outlets, or general-purpose distribution. The 4.5 kA Icn breaking capacity at 220–240 V AC conforms to EN/IEC 61009-2-1. That figure governs the maximum prospective fault current the device can safely interrupt. In a typical domestic or small commercial distribution board with a 6 kA or 10 kA upstream main breaker, this 4.5 kA rating means the RCBO is suitable for outgoing circuits where the fault level at the point of installation does not exceed that value — a coordination check the panel builder must confirm. The limitation class 3 rating (also per EN/IEC 61009-2-1) indicates good energy let-through performance, which helps with downstream selectivity. The integrated 30 mA residual current sensitivity covers the standard requirement for additional protection against direct contact in most IEC 60364 installations. The thermal-magnetic trip unit handles the overcurrent side — the thermal element protects against sustained overloads, the magnetic element against short-circuits. The device is rated for 20,000 electrical and 20,000 mechanical cycles, which is a solid endurance figure for a distribution RCBO. The 9 mm pitch between phase and neutral connections matches the Acti9 busbar system. The toggle provides local ON, OFF, and fault-trip indication.","metaTitle":"Schneider Electric A9D54613 Acti9 iDPN Vigi RCBO, 13A B-Curv","metaDescription":"Schneider Electric A9D54613 Acti9 iDPN Vigi RCBO. 13A rated, B-curve, 30mA RCD, 4.5kA breaking capacity. 1P+N, DIN rail mount. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iDPN Vigi","Mounting mode":"Clip-on","Surge current":"250 A","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"4500 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"iDPNa Vigi","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"13 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm for top or bottom connection","Connections - terminals":"Single terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 4500 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"4500 A 100 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/sg/en/product/A9D54613/acti9-idpna-vigi-rcbo-1p+n-13a-b-curve-4500a-30ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D54613/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9D54613?","answer":"The A9D54613 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of A9D54613?","answer":"The A9D54613 has a breaking capacity of 4500 A Icn at 220...240 V AC 50 Hz, conforming to EN/IEC 61009-2-1."},{"question":"What is the residual current sensitivity of A9D54613?","answer":"The integrated earth-leakage protection is rated at 30 mA sensitivity."},{"question":"What compliance documentation does this brand provide for A9D54613?","answer":"The A9D54613 is certified to EN/IEC 61009-2-1 and carries overvoltage category III per IEC 60364. It is tropicalised to class 2 per IEC 60068-1. Specific RoHS/REACH declarations are available from the manufacturer upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D54613","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D54613 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}