{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D56706","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D56706","canonicalUrl":"https://aoctrl.com/schneider/A9D56706","factsUrl":"https://aoctrl.com/api/mcp/products/A9D56706","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN Vigi RCBO, A9D56706, 6 A rated current, curve B, 30 mA earth-leakage sensitivity, 6 kA breaking capacity, 3P+N, DIN-rail mount.","salesMarkdown":"The Schneider Electric A9D56706 is an Acti9 DPN Vigi RCBO — a combined overcurrent and residual-current device in a single 3P+N module. Rated 6 A with a curve B trip characteristic (magnetic tripping between 3 and 5 times In), it integrates 30 mA earth-leakage protection for personnel safety. The 6 kA breaking capacity at 380–415 V AC (EN/IEC 61009-2-1) covers most residential and light commercial outgoing circuits. The 6 A rated current (In) is the continuous load the RCBO can carry without tripping. Curve B means the magnetic trip fires at 3–5 times In — so between 18 A and 30 A — making it suitable for resistive or lightly inductive loads where inrush is low. The 30 mA residual sensitivity is the standard for socket-outlet and personnel protection in most IEC-based codes. Breaking capacity of 6 kA Icn at 380–415 V AC means it can safely interrupt a fault current up to 6 kA without welding contacts or cascading damage upstream. The thermal-magnetic trip unit handles both overload (thermal bimetal) and short-circuit (magnetic coil) in one package. Clip-on mounting onto a DIN rail (35 mm). The tunnel-type terminals accept rigid cable from 0.75 mm² up to 16 mm², or flexible cable 0.33–10 mm² (with or without ferrule). The connection pitch is 18 mm between phases and 9 mm between phase and neutral — standard for Acti9 modular devices. Pollution degree 3 (industrial environment) and overvoltage category III (distribution board level). IP20 on the terminals, IP40 on the modular enclosure.","metaTitle":"Schneider Electric A9D56706 Acti9 DPN Vigi, 6 A Curve B, 30","metaDescription":"Schneider Electric A9D56706 Acti9 DPN Vigi RCBO, 6 A rated current, curve B, 30 mA earth leakage, 6 kA breaking capacity, EN/IEC 61009-2-1. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"90 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"10","Control type":"Toggle","Network type":"AC","Product name":"Acti9 DPN Vigi","Mounting mode":"Clip-on","Surge current":"250 A","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"18 mm between phases 9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"6000 A Icn at 380...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Device short name":"DPN N Vigi","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"90 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"6 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 0.75...16 mm² rigid Tunnel type terminal top or bottom 0.33...10 mm² flexible Tunnel type terminal top or bottom 0.33...10 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"3","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device Sealable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"440 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"380...415 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 6000 A at 380...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-30...70 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 380...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/A9D56706/acti9-dpn-n-vigi-rcbo-3p+n-6a-b-curve-6000a-30ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D56706/alternatives.json"},"ai":{"faq":[{"question":"Who supplies A9D56706 and how is it quoted for volume purchases?","answer":"We source this part through independent distribution channels. Submit an RFQ for current pricing and availability — both are confirmed at quote time."},{"question":"What is A9D56706's listed depth (78.5 mm) on this component line?","answer":"The depth is 78.5 mm. Combined with the 90 mm width and 91 mm height, it occupies a standard 3P+N modular space on the DIN rail."},{"question":"What is A9D56706's listed range (Acti9) on this component line?","answer":"It belongs to the Schneider Electric Acti9 range, specifically the DPN Vigi sub-family of RCBOs."},{"question":"What compliance documentation does this brand provide for A9D56706 (RoHS, REACH, UL, IEC)?","answer":"The part is designed and tested to EN/IEC 61009-2-1. It carries a limitation class 3 and tropicalisation class 2 per IEC 60068-1. For RoHS/REACH declarations and any UL listing, refer to the manufacturer's documentation or request it with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D56706","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D56706 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}