{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D56840","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D56840","canonicalUrl":"https://aoctrl.com/schneider/A9D56840","factsUrl":"https://aoctrl.com/api/mcp/products/A9D56840","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60 RCBO, 1P+N, 40 A, 30 mA, B-curve, 10 kA, 1 module (18 mm).","salesMarkdown":"Rated 40 A at 50 °C with 30 mA earth-leakage sensitivity, it integrates both thermal-magnetic overcurrent and GFCI protection into one DIN-rail footprint, saving a full module width versus separate breaker and RCCB. Breaking capacity is 10 kA Icn at 240 V AC, 50/60 Hz, certified to IEC 61009-2-2 and BS EN 61009-1 — sufficient for most residential and light commercial distribution boards where the prospective fault current stays under 10 kA. The B-curve (magnetic trip 3–5 × In) suits resistive and general-purpose loads; it avoids nuisance trips on moderate inrush. IP20 finger-safe terminals; IP40 in a modular enclosure. Terminal capacity: 1–25 mm² rigid top, 1–16 mm² rigid bottom. Tightening torque 3.5 N·m top, 2 N·m bottom. Designed to IEC 61009-1 and IEC 61009-2-2, plus BS EN 61009-1. Rated for TN earthing systems. Overvoltage category II. Tropicalisation class 2 (95 % RH at 55 °C). Electrical durability 5,000 cycles; mechanical durability 20,000 cycles. ## Integration notes Mounts on standard DIN rail via plug-on mechanism. The 18 mm width (1 module) fits compactly in distribution boards where space is tight. Use the top screw terminal for incoming line (1–25 mm² rigid), bottom for outgoing (1–16 mm² rigid). Wire stripping length: 14 mm top, 13 mm bottom. The integrated earth-leakage protection eliminates the need for a separate RCCB downstream — one device, one module, one part number on the BOM.","metaTitle":"Schneider Electric A9D56840 Acti9 iC60 RCBO, 40 A, 30 mA, Ty","metaDescription":"Schneider Electric A9D56840 Acti9 iC60 RCBO, 40 A rated, 30 mA earth leakage, 10 kA breaking capacity. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"72 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"110 mm","Standards":"IEC 61009-2-2 IEC 61009-1 BS EN 61009-1","Curve code":"B","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Mounting mode":"Plug-on","Surge current":"250 A","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication Fault indication","Mounting support":"Isobar B Isobar A","Neutral position":"Left","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to IEC 61009-2-2","Device short name":"iC60H RCBO PoN","Network frequency":"50/60 Hz","Poles description":"1P + Ns","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top 2 N.m bottom","[In] rated current":"40 A at 50 °C","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top connection 13 mm for bottom connection","Connections - terminals":"Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...10 mm² flexible Screw clamp terminal (top) 1...25 mm² rigid Screw clamp terminal (bottom) 1...16 mm² rigid Plug-on neutral (upstream)","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Electrical insulation class":"Class II","Locking options description":"Padlock in on or off position","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230/240 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-15...60 °C","[Ics] rated service breaking capacity":"7500 A at 240 V AC 50/60 Hz conforming to IEC 61009-2-2","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$197.56","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/A9D56840/acti9-ic60h-rcbo-plug-on-neutral-1p+ns-40a-b-10000a-30ma-type-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D56840/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9D56840?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm offer."},{"question":"What is the breaking capacity of A9D56840?","answer":"10,000 A Icn at 240 V AC, 50/60 Hz, certified to IEC 61009-2-2."},{"question":"What is the earth-leakage sensitivity of A9D56840?","answer":"30 mA, integrated into the same device as the overcurrent protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D56840","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D56840 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}