{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D60606","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D60606","canonicalUrl":"https://aoctrl.com/schneider/A9D60606","factsUrl":"https://aoctrl.com/api/mcp/products/A9D60606","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iDPN Vigi RCBO, A9D60606, 6 A rated, B-curve, 6 kA breaking capacity, 100 mA earth leakage, 1P+N, DIN rail mount.","salesMarkdown":"The Schneider Electric A9D60606 is an Acti9 iDPN Vigi RCBO — a combined miniature circuit breaker and residual-current device in a single 36 mm wide module, 1P+N configuration, rated 6 A with a B-curve trip characteristic and 100 mA earth-leakage sensitivity. The 6 A rated current (In) and B-curve (magnetic trip at 3 to 5 times In) mean this RCBO is sized for lighting circuits, small appliance loads, or control transformers — not motor or high-inrush loads. The 6 kA breaking capacity (Icn at 230–240 V AC, 50 Hz, per EN/IEC 61009-2-1) is the standard domestic-commercial fault-interrupting rating; it safely clears a short-circuit up to 6 kA without welding the contacts or cascading damage upstream. The 100 mA earth-leakage threshold provides personnel and equipment protection against ground faults, not the 30 mA level used for direct human contact protection — so it suits submain or distribution circuits where a lower sensitivity would cause nuisance tripping. Thermal-magnetic trip technology gives the bimetal overload curve for sustained overcurrents and the solenoid for short-circuit response. Neutral is on the left, phase on the right — check your busbar orientation before wiring. Terminals accept 1 to 16 mm² rigid or 1 to 10 mm² flexible, with a 15 mm strip length and 2 Nm tightening torque. The 9 mm pitch between phase and neutral terminals is the standard for modular RCBOs in this form factor.","metaTitle":"Schneider Electric A9D60606 Acti9 iDPN Vigi, 6A B-curve RCBO","metaDescription":"Schneider Electric A9D60606 Acti9 iDPN Vigi RCBO, 6 A rated, B-curve, 6 kA breaking capacity, 100 mA earth leakage, 1P+N, DIN rail mount. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iDPN Vigi","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"6000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"iDPN N Vigi","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"6 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm for top or bottom connection","Connections - terminals":"Single terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"100 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/sg/en/product/A9D60606/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1p+n-6a-b-curve-6000a-a-type-100ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D60606/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the A9D60606 and get a price?","answer":"The A9D60606 is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — no stock or price figures are published here."},{"question":"What is the breaking capacity of the A9D60606?","answer":"The A9D60606 has a breaking capacity of 6000 A Icn at 230–240 V AC, 50 Hz, conforming to EN/IEC 61009-2-1."},{"question":"What earth-leakage sensitivity does the A9D60606 provide?","answer":"The integrated earth-leakage protection is set at 100 mA sensitivity — suitable for submain or distribution circuits where 30 mA would cause nuisance tripping."},{"question":"What compliance documentation does Schneider provide for the A9D60606?","answer":"The A9D60606 is certified to EN/IEC 61009-2-1, carries overvoltage category III per IEC 60364, pollution degree 3, and tropicalisation class 2 per IEC 60068-1. The manufacturer provides the standard declaration of conformity and product certificate — request these with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D60606","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D60606 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}