{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D61610","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D61610","canonicalUrl":"https://aoctrl.com/schneider/A9D61610","factsUrl":"https://aoctrl.com/api/mcp/products/A9D61610","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iDPN Vigi RCBO, 1P+N, 10 A, C-curve, 30 mA earth leakage, 6 kA breaking capacity, DIN rail clip-on.","salesMarkdown":"The Schneider Electric A9D61610 is an Acti9 iDPN Vigi residual-current circuit breaker with overcurrent protection (RCBO) — a single-module (36 mm wide) 1P+N device rated 10 A, C-curve, with integrated 30 mA earth-leakage protection. Breaking capacity is 6000 A Icn at 110…240 V AC, 50 Hz, certified to EN/IEC 61009-2-1. That rating covers the majority of domestic and light-commercial fault levels; for higher prospective short-circuit currents you would step to a higher-breaking variant. Rated current 10 A with C-curve means the breaker holds 10 A continuously and trips instantaneously on a fault between 50 A and 100 A. That suits general-purpose socket circuits and lighting loads where inrush from small motors or LED drivers is moderate. The 30 mA residual sensitivity is the standard threshold for supplementary protection against electric shock in TN and TT systems. It also provides fire protection for circuits where the earth-fault impedance is low enough to sustain an arc below the overcurrent trip threshold. The 9 mm pitch between phase and neutral terminals is a standard Acti9 dimension — the busbar comb and plug-in accessories for the range fit without modification. Neutral is on the left, which matters when wiring a pre-bussed panel. IP20 on the front (finger-safe) and IP40 inside the modular enclosure — standard for distribution boards. The toggle provides local ON/OFF/fault-trip indication; the fault-trip position is mechanically distinct from the OFF position, which helps during troubleshooting.","metaTitle":"Schneider Electric A9D61610 Acti9 iDPN Vigi, 10 A, 30 mA, C-","metaDescription":"Schneider Electric A9D61610 Acti9 iDPN Vigi RCBO, 10 A, 30 mA, C-curve, 6 kA, 1P+N, DIN rail. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iDPN Vigi","Mounting mode":"Clip-on","Surge current":"250 A","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"6000 A Icn at 110...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"iDPN N Vigi","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"10 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm for top or bottom connection","Connections - terminals":"Single terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"110...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 110...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 110...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9D61610/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1p+n-10a-c-curve-6000a-ac-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D61610/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D61610","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D61610 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}