{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D61620","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D61620","canonicalUrl":"https://aoctrl.com/schneider/A9D61620","factsUrl":"https://aoctrl.com/api/mcp/products/A9D61620","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iDPN Vigi, 1P+N RCBO, 20 A rated current, C-curve, 30 mA earth-leakage sensitivity, 6 kA breaking capacity, DIN rail mount.","salesMarkdown":"The Schneider Electric A9D61620 is a 1P+N RCBO from the Acti9 iDPN Vigi range, combining overcurrent and earth-leakage protection in a single 36 mm wide DIN-rail module. It carries a 20 A rated current with a C-curve magnetic trip (5...10 x In) and 30 mA earth-leakage sensitivity, so it protects both the circuit and personnel against ground faults. The breaking capacity is 6000 A Icn at 110...240 V AC, 50 Hz, per EN/IEC 61009-2-1 — enough for most residential and light commercial distribution boards where the prospective fault current stays under that threshold. The 20 A thermal-magnetic trip is sized for lighting, socket-outlet, or small-appliance circuits drawing up to 16 A continuous load — standard practice is to derate to 80% of the breaker rating for continuous loads per IEC 60364. The 30 mA residual-current element provides personnel protection (30 mA is the IEC threshold for preventing ventricular fibrillation) and also covers fire-risk detection from leakage to earth. The limitation class 3 means the RCBO limits let-through energy to a low level, which helps with downstream coordination and reduces arc-flash stress on the connected equipment. Integrated earth-leakage protection eliminates the need for a separate RCCB upstream for this circuit — the iDPN Vigi packs both overcurrent and residual-current functions into one 4-pitch (36 mm) module. That saves two DIN spaces compared to a separate MCB + RCCB pair, which matters when the panel fill factor is tight. Clip-on mounting onto a standard DIN rail — no screws needed for the rail attachment. The IP20 rating covers the terminals against finger contact; the modular enclosure achieves IP40 inside the panel, so it's suited for distribution boards in dry indoor environments. The toggle provides local ON, OFF, and fault-trip indication — a red flag or a tripped position that stays visible even after the handle is reset, which speeds up fault isolation on a multi-circuit board.","metaTitle":"Schneider Electric A9D61620 Acti9 iDPN Vigi, 20 A C-curve 30","metaDescription":"Schneider Electric Acti9 iDPN Vigi RCBO, 20 A rated current, C-curve, 30 mA earth-leakage, 6 kA breaking capacity. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iDPN Vigi","Mounting mode":"Clip-on","Surge current":"250 A","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"6000 A Icn at 110...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"iDPN N Vigi","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"20 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm for top or bottom connection","Connections - terminals":"Single terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"110...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 110...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 110...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9D61620/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1p+n-20a-c-curve-6000a-ac-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D61620/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9D61620?","answer":"The breaking capacity is 6000 A Icn at 110...240 V AC, 50 Hz, conforming to EN/IEC 61009-2-1."},{"question":"What is the earth-leakage sensitivity of A9D61620?","answer":"The earth-leakage sensitivity is 30 mA, integrated into the RCBO."},{"question":"Where can I buy A9D61620?","answer":"The A9D61620 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D61620","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D61620 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}