{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D61625","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D61625","canonicalUrl":"https://aoctrl.com/schneider/A9D61625","factsUrl":"https://aoctrl.com/api/mcp/products/A9D61625","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iDPN Vigi RCBO, 1P+N, 25 A, C-curve, 30 mA earth leakage, 6 kA breaking capacity, DIN-rail mount.","salesMarkdown":"It protects a final subcircuit against overload, short-circuit (thermal-magnetic trip, C-curve, magnetic tripping limit 5...10 x In), and earth leakage at 30 mA sensitivity. Breaking capacity is 6000 A Icn at 110...240 V AC 50 Hz, conforming to EN/IEC 61009-2-1. Clip-on mounting on DIN rail, 4 x 9 mm pitches wide (36 mm). Neutral is on the left. Terminals accept 1...16 mm² rigid or 1...10 mm² flexible (with or without ferrule); tightening torque 2 N.m. IP20 finger-safe, IP40 in a modular enclosure.","metaTitle":"Schneider Electric A9D61625 Acti9 iDPN Vigi RCBO, 25 A C-cur","metaDescription":"Schneider Electric A9D61625 Acti9 iDPN Vigi RCBO, 25 A rated, C-curve, 30 mA earth leakage, 6 kA breaking capacity. DIN-rail mount, current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iDPN Vigi","Mounting mode":"Clip-on","Surge current":"250 A","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"6000 A Icn at 110...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"iDPN N Vigi","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"25 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm for top or bottom connection","Connections - terminals":"Single terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"110...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 110...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 110...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9D61625/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1p+n-25a-c-curve-6000a-ac-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D61625/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to A9D61625 in the Acti9 family?","answer":"Within the Acti9 iDPN Vigi range, the A9D61625 is the 25 A C-curve 30 mA variant. The closest sibling would be a different rated-current or curve-code version (e.g., A9D61616 for 16 A, or A9D61625 for B-curve if available) — check the spec line for your required In and curve before substituting."},{"question":"What compliance documentation does Schneider provide for A9D61625?","answer":"The device is certified to EN/IEC 61009-2-1, carries overvoltage category III per IEC 60364, pollution degree 3, and tropicalisation class 2 per IEC 60068-1. Standard Schneider documentation includes the declaration of conformity; RoHS and REACH compliance data is available on request."},{"question":"Where can I buy A9D61625 and how is it quoted?","answer":"The A9D61625 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time estimate."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D61625","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D61625 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}