{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D68610","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D68610","canonicalUrl":"https://aoctrl.com/schneider/A9D68610","factsUrl":"https://aoctrl.com/api/mcp/products/A9D68610","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iDPN Vigi RCBO, order code A9D68610, 10 A rated, B-curve, 6 kA breaking capacity, 300 mA earth leakage, 1P+N, DIN rail.","salesMarkdown":"The Schneider Electric A9D68610 is an Acti9 iDPN Vigi residual current circuit breaker with overcurrent protection (RCBO) — a combined 1P+N MCB and 30 mA or 300 mA earth-leakage block in a single 36 mm wide module. Rated 10 A with a B-curve (magnetic trip at 3–5 × In) and a 6 kA breaking capacity at 230 V AC, it clips onto a DIN rail in a distribution board as an outgoing circuit for lighting or socket-outlet protection where both overcurrent and earth-leakage protection are required in one device. The 73 mm depth fits standard 85 mm tall enclosures. Earth-leakage sensitivity is 300 mA (fixed), which provides equipment protection (fire prevention) rather than personal shock protection; for personnel protection a 30 mA variant would be used. Integrated earth leakage means no separate RCCB module is needed, saving one DIN module width.","metaTitle":"Schneider Electric A9D68610 Acti9 iDPN Vigi, 10 A B-curve 6","metaDescription":"Schneider Electric A9D68610 Acti9 iDPN Vigi RCBO, 10 A, B-curve, 6 kA breaking capacity, 300 mA earth leakage, 1P+N, DIN rail. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iDPN Vigi","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"6000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"iDPN N Vigi","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"10 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm for top or bottom connection","Connections - terminals":"Single terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/sg/en/product/A9D68610/acti9-idpn-n-vigi-rcbo-1p+n-10a-b-curve-6000a-300ma-type-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D68610/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9D68610?","answer":"Submit an RFQ through this listing; pricing and stock are confirmed at quote time and vary by quantity and channel."},{"question":"What is the breaking capacity of A9D68610?","answer":"The breaking capacity is 6000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1."},{"question":"What standards does A9D68610 comply with?","answer":"It complies with EN/IEC 61009-2-1 for RCBOs, and the limitation class is 3 per that standard."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D68610","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D68610 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}