{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D83606T","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D83606T","canonicalUrl":"https://aoctrl.com/schneider/A9D83606T","factsUrl":"https://aoctrl.com/api/mcp/products/A9D83606T","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 ISPN Vigi RCBO, 1P+N, 6 A rated current, C-curve, 30 mA earth-leakage sensitivity, 10 kA breaking capacity, 18 mm width, clip-on DIN rail mounting.","salesMarkdown":"The 10 kA breaking capacity at 230/240 V AC (Icn per AS/NZS 61009.1) is sized for residential and light commercial sub-distribution where the prospective fault current stays under that threshold. Rated at 6 A with a C-curve magnetic trip threshold of 5 to 10 times In, so it clears moderate inrush from motorized loads and fluorescent ballasts without nuisance tripping — but the 6 A frame limits the connected load to roughly 1.4 kW resistive or 1.1 kW motor (230 V). The integrated 30 mA residual-current element covers personnel protection (30 mA is the standard threshold for indirect-contact protection per AS/NZS 3000). Breaking capacity of 10 kA at 230/240 V AC 50 Hz places it in limitation class 3, meaning it limits let-through energy enough to coordinate with a downstream 4.5 kA MCB in most domestic panels. Pollution degree 2 and tropicalisation level 2 confirm it for normal indoor environments with non-condensing humidity up to 95 % at 55 °C. Terminals accept up to 25 mm² rigid upstream and 16 mm² rigid downstream; tightening torque is 3.5 N.m upstream, 2 N.m downstream. Strip length 14 mm upstream, 13 mm downstream — a detail that matters when terminating in a crowded enclosure. The toggle is padlockable (Ø 4 mm padlock) for lockout/tagout during maintenance. Width is 18 mm (2 x 9 mm pitches) on a 45 mm grid distance. Clips onto standard DIN rail (35 mm) with the neutral on the left. IP20 finger-safe terminals are acceptable in an enclosed distribution board but not for wet or dusty locations. Electrical durability is 6000 cycles; mechanical durability 10 000 cycles — adequate for a final-circuit breaker switched infrequently.","metaTitle":"A9D83606T Acti9 ISPN Vigi RCBO, 6 A, C-curve, 30 mA, 10 kA","metaDescription":"A9D83606T Acti9 ISPN Vigi RCBO, 6 A rated, C-curve, 30 mA earth leakage, 10 kA breaking capacity, 1P+N, 18 mm, clip-on DIN rail. AS/NZS 61009.1. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Range":"Acti9","Width":"18 mm","Colour":"White","Standards":"AS/NZS 61009.1","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"ISPN Vigi","Grid distance":"45 mm","Mounting mode":"Clip-on","Surge current":"250 A","Operating mode":"Bidirectional","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail Chassis","Neutral position":"Left","Pollution degree":"2","Breaking capacity":"10000 A Icn at 230/240 V AC 50 Hz","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m upstream 2 N.m downstream","[In] rated current":"6 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"6000 cycles","Mechanical durability":"10000 cycles","Wire stripping length":"13 mm for downstream connection 14 mm for upstream connection","Connections - terminals":"Tunnel type terminal (upstream) 1...25 mm² rigid Tunnel type terminal (downstream) 1...16 mm² rigid Tunnel type terminal (upstream) 1...16 mm² flexible Tunnel type terminal (downstream) 1...10 mm² flexible","IP degree of protection":"IP20","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to IEC 61009-1","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Locking options description":"Handle sealable with cable diameter 1.4mm in OFF or ON position","Test button operating voltage":"140...264 V","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230/240 V AC 50 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7500 A","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"YES","Operating voltage for protection against earth-leakage":"85...264 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nz/en/product/A9D83606T/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ispn-h-vigi-1p-+-n-6a-30ma-a-type-c-curve-10000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D83606T/alternatives.json"},"ai":{"faq":[{"question":"What is A9D83606T's breaking capacity and what does it mean?","answer":"The breaking capacity is 10 000 A Icn at 230/240 V AC 50 Hz. That means it can safely interrupt a fault current up to 10 kA without failing — sufficient for most residential and light commercial final circuits where the prospective short-circuit current is below that level."},{"question":"What is the closest alternative to A9D83606T in the same family?","answer":"Within the Acti9 ISPN Vigi range, the closest alternative is a unit with the same 1P+N, 30 mA, C-curve configuration but a different rated current — for example a 10 A or 16 A variant. There is no pin-compatible direct substitute; the selection is driven by the load current requirement."},{"question":"Where can I buy A9D83606T?","answer":"The A9D83606T is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quotation."},{"question":"What compliance standards does A9D83606T meet?","answer":"The A9D83606T is certified to AS/NZS 61009.1, the Australian/New Zealand standard for RCBOs. It is designed for TN earthing systems and rated for pollution degree 2 indoor environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D83606T","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D83606T when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}