{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D83625T","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D83625T","canonicalUrl":"https://aoctrl.com/schneider/A9D83625T","factsUrl":"https://aoctrl.com/api/mcp/products/A9D83625T","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 ISPN Vigi RCBO, 1P+N, 25 A, C-curve, 30 mA earth-leakage sensitivity, 10 kA breaking capacity at 230/240 V AC.","salesMarkdown":"It combines a C-curve thermal-magnetic MCB and a 30 mA earth-leakage module in a single 18 mm wide unit that clips onto a DIN rail. The 25 A rated current (In) and C-curve magnetic trip (5 to 10 x In) mean this RCBO handles general-purpose loads like lighting, socket outlets, and small appliances that produce moderate inrush — the C curve is the standard choice for mixed resistive-inductive circuits in commercial fit-outs. The 30 mA earth-leakage sensitivity provides personal protection against direct contact, meeting the threshold required by most wiring regulations for socket circuits. The limitation class 3 rating means the device limits let-through energy under fault, reducing stress on downstream wiring. The tunnel-type terminals accept ferruled stranded as well; strip length is 13 mm downstream and 14 mm upstream. Mechanical durability is 10 000 cycles, electrical durability 6 000 cycles. Width is 18 mm (2 x 9 mm pitches). IP20 rated, so suitable for enclosure interiors but not washdown zones. Provision for padlocking with a 4 mm padlock for lockout/tagout during maintenance. Certified to AS/NZS 61009.1, the Australian/New Zealand standard for RCBOs. The Acti9 range is Schneider Electric's current-generation DIN-rail protection platform, so this part carries the manufacturer's standard warranty and technical support. Pollution degree 2, tropicalisation class 2.","metaTitle":"Schneider Electric A9D83625T Acti9 ISPN Vigi RCBO, C-Curve 2","metaDescription":"Schneider Electric A9D83625T Acti9 ISPN Vigi RCBO. 1P+N, 25 A rated current, C-curve, 30 mA earth leakage, 10 kA breaking capacity. AS/NZS 61009.1. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Range":"Acti9","Width":"18 mm","Colour":"White","Standards":"AS/NZS 61009.1","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"ISPN Vigi","Grid distance":"45 mm","Mounting mode":"Clip-on","Surge current":"250 A","Operating mode":"Bidirectional","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail Chassis","Neutral position":"Left","Pollution degree":"2","Breaking capacity":"10000 A Icn at 230/240 V AC 50 Hz","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m upstream 2 N.m downstream","[In] rated current":"25 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"6000 cycles","Mechanical durability":"10000 cycles","Wire stripping length":"13 mm for downstream connection 14 mm for upstream connection","Connections - terminals":"Tunnel type terminal (upstream) 1...25 mm² rigid Tunnel type terminal (downstream) 1...16 mm² rigid Tunnel type terminal (upstream) 1...16 mm² flexible Tunnel type terminal (downstream) 1...10 mm² flexible","IP degree of protection":"IP20","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to IEC 61009-1","Contact position indicator":"Yes","Circuit breaker application":"Distribution","Locking options description":"Handle sealable with cable diameter 1.4mm in OFF or ON position","Test button operating voltage":"140...264 V","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230/240 V AC 50 Hz","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7500 A","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"YES","Operating voltage for protection against earth-leakage":"85...264 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nz/en/product/A9D83625T/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ispn-h-vigi-1p-+-n-25a-30ma-a-type-c-curve-10000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D83625T/alternatives.json"},"ai":{"faq":[{"question":"What is the A9D83625T used for?","answer":"It is a combined overcurrent and earth-leakage protection device (RCBO) for 1P+N circuits. Use it on 230/240 V AC socket circuits, lighting circuits, and small appliance feeds where both short-circuit, overload, and 30 mA earth-leakage protection are required in a single 18 mm DIN-rail module."},{"question":"Where can I buy the A9D83625T?","answer":"This part is sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm delivery schedule."},{"question":"What is the breaking capacity of the A9D83625T?","answer":"10 000 A Icn at 230/240 V AC, 50 Hz. That is the rated short-circuit breaking capacity the device can safely interrupt under fault conditions."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D83625T","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D83625T when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}