{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D87410","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D87410","canonicalUrl":"https://aoctrl.com/schneider/A9D87410","factsUrl":"https://aoctrl.com/api/mcp/products/A9D87410","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60 RCBO, order code A9D87410, 4-pole, 10 A rated current, B-curve, 30 mA earth-leakage sensitivity, 6 kA breaking capacity, clip-on DIN rail mount.","salesMarkdown":"The Schneider Electric A9D87410 is a 4-pole Acti9 iC60 RCBO — a combined overcurrent and earth-leakage protection device rated at 10 A with a B-curve trip characteristic and 30 mA residual-current sensitivity, breaking capacity of 6 kA at 380–415 V AC. It clips onto DIN rail and fits in a distribution board as an outgoer for final circuits where both short-circuit and ground-fault protection are needed in one unit. The 10 A rated current and B-curve (magnetic trip at 3–5× In) make this RCBO suited for lighting and general-purpose socket circuits where inrush is modest. The 30 mA earth-leakage sensitivity provides personal protection against indirect contact — standard for most residential and commercial final circuits. Breaking capacity of 6 kA at 380–415 V AC is the Icn per EN/IEC 61009-2-1 and the Icu per EN/IEC 60947-2; 6 kA covers typical domestic and light commercial fault levels, but if your service entrance has a higher prospective short-circuit current, you'll need to check coordination upstream. The thermal-magnetic trip unit handles overloads (thermal) and short-circuits (magnetic) in one block. The device is marked with limitation class 1 per EN/IEC 61009-2-1, meaning it lets through a moderate amount of let-through energy under fault — fine for most final circuits, but if you're chasing tight selectivity with upstream breakers, class 3 (current-limiting) devices are a better choice. Clip-on mounting to DIN rail, 4-pole width occupies 8 pitches of 9 mm (72 mm total). Tunnel-type terminals accept 1–35 mm² rigid or 1–25 mm² flexible cable; wire strip length is 12 mm for top or bottom connection. Tightening torque 2 N·m. The IP40 rating in a distribution enclosure is typical for indoor panels; the device itself carries IP20. Local signalling shows ON, OFF, and fault-trip status on the toggle.","metaTitle":"Schneider A9D87410 Acti9 iC60 RCBO, 4P, 10A, B-curve, 30mA,","metaDescription":"Schneider Electric A9D87410 Acti9 iC60 RCBO, 4-pole, 10 A rated, B-curve, 30 mA earth leakage, 6 kA breaking capacity, clip-on DIN rail. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"78 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"86 mm","Standards":"EN/IEC 60947-2 EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Mounting mode":"Clip-on","Surge current":"250 A","Quality labels":"IMQ NF KEMA-KEUR VDE","Tropicalisation":"2","lifecycle_stage":"current","Connection pitch":"9 mm between poles","Limitation class":"1 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"6000 A Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 6 kA Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"iC60 RCBO","Network frequency":"50 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"10 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule","IP degree of protection":"IP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"4","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"No conforming to IEC 60947-1","Contact position indicator":"No","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"380...415 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...70 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 6 kA 100 % x Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES Bottom: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/A9D87410/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ic60-4p-10a-b-curve-6000a-6ka-a-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D87410/alternatives.json"},"ai":{"faq":[{"question":"What is A9D87410's listed depth?","answer":"The depth is 78 mm."},{"question":"What is A9D87410's range?","answer":"It belongs to the Acti9 range from Schneider Electric."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D87410","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D87410 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}