{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D97410","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D97410","canonicalUrl":"https://aoctrl.com/schneider/A9D97410","factsUrl":"https://aoctrl.com/api/mcp/products/A9D97410","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60 RCBO, 4P, 10 A rated, 30 mA earth leakage, B-curve, 6 kA breaking capacity, clip-on DIN rail mount.","salesMarkdown":"The Schneider Electric A9D97410 is an Acti9 iC60 RCBO — a combined residual-current circuit breaker with overcurrent protection, in a 4-pole (4P) configuration. Rated 10 A with 30 mA earth-leakage sensitivity and a B-curve magnetic trip (3–5 x In), it's built for final-circuit protection in distribution boards where both overload/short-circuit and earth-fault protection are needed in one DIN-rail module. The 30 mA earth-leakage threshold provides personnel protection (per IEC 61009-2-1) and is the standard sensitivity for socket-outlet circuits in most domestic and commercial installations. The limitation class 1 (per EN/IEC 61009-2-1) means it lets through a defined let-through energy; coordination with upstream devices should follow the manufacturer's selectivity tables. Clip-on mounting to DIN rail, 9 mm pole pitch, occupying 8 pitches (72 mm width). IP40 in a distribution enclosure, IP20 at the terminals — fine for a clean panel, not for washdown areas.","metaTitle":"Schneider Electric A9D97410 Acti9 iC60 RCBO, 4P, 10 A, 30 mA","metaDescription":"Schneider Electric A9D97410 Acti9 iC60 RCBO, 4P, 10 A, 30 mA earth leakage, B-curve, 6 kA breaking capacity. Current-production part, sourced to order. Get a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"78 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"86 mm","Standards":"EN/IEC 60947-2 EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Mounting mode":"Clip-on","Surge current":"3000 A","Quality labels":"NF VDE KEMA-KEUR IMQ","Tropicalisation":"2","lifecycle_stage":"current","Connection pitch":"9 mm between poles","Limitation class":"1 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"6000 A Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 6 kA Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"iC60 RCBO","Network frequency":"50 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"10 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule","IP degree of protection":"IP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"4","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"No conforming to IEC 60947-1","Contact position indicator":"No","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"380...415 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...70 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 6 kA 100 % x Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES Bottom: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/A9D97410/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ic60-4p-10a-b-curve-6000a-6ka-asi-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D97410/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9D97410?","answer":"Submit an RFQ through this listing. Pricing and stock are confirmed at quote time; we source this current-production part to order."},{"question":"What is A9D97410's listed depth (78 mm) on this component line?","answer":"The A9D97410 has a depth of 78 mm, a width of 72 mm (8 x 9 mm pitches), and a height of 86 mm."},{"question":"What is A9D97410's listed range (Acti9) on this component line?","answer":"A9D97410 belongs to the Schneider Electric Acti9 range, specifically the iC60 RCBO series."},{"question":"What compliance documentation does this brand provide for A9D97410 (RoHS, REACH, UL, IEC)?","answer":"The A9D97410 is certified to EN/IEC 60947-2 and EN/IEC 61009-2-1, and carries quality labels NF, VDE, KEMA-KEUR, and IMQ. The manufacturer typically provides RoHS and REACH declarations on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D97410","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D97410 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}