{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9D97420","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9D97420","canonicalUrl":"https://aoctrl.com/schneider/A9D97420","factsUrl":"https://aoctrl.com/api/mcp/products/A9D97420","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60 RCBO, 4P, 20 A rated current, 30 mA earth leakage, B curve, 6 kA breaking capacity, DIN rail mount, white.","salesMarkdown":"The A9D97420 is a 4-pole Acti9 iC60 RCBO — a combined residual-current circuit breaker with overcurrent protection, rated 20 A with 30 mA earth-leakage sensitivity. The B-curve characteristic (3 to 5 x In magnetic trip) means it's sized for resistive or light inductive loads — lighting, small heaters, control transformers — where inrush isn't a concern. The 9 mm pole pitch keeps the width to 72 mm for the 4P version — eight 9 mm pitches total. Strip 12 mm for the connection. That's a straightforward fit for a panel OEM or a swap on an existing Acti9 board. ## Compliance and approvals at a glance Overvoltage category III per IEC 60364.","metaTitle":"Schneider Electric A9D97420 Acti9 iC60 RCBO, 20A, 30mA, B Cu","metaDescription":"Schneider Electric A9D97420 Acti9 iC60 RCBO. 4P, 20A rated, 30mA earth leakage, B curve, 6kA breaking capacity. DIN rail mount, current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"78 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"86 mm","Standards":"EN/IEC 60947-2 EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Mounting mode":"Clip-on","Surge current":"3000 A","Quality labels":"NF IMQ VDE KEMA-KEUR","Tropicalisation":"2","lifecycle_stage":"current","Connection pitch":"9 mm between poles","Limitation class":"1 conforming to EN/IEC 61009-2-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"6000 A Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 6 kA Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"iC60 RCBO","Network frequency":"50 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"20 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule","IP degree of protection":"IP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"4","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"No conforming to IEC 60947-1","Contact position indicator":"No","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"380...415 V AC 50 Hz","Rated breaking and making capacity":"Idm 6000 A at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...70 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 6 kA 100 % x Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: YES Bottom: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/A9D97420/acti9-ic60-rcbo-4p-20-a-b-curve-6000a-6ka-30-ma-si-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9D97420/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9D97420?","answer":"The breaking capacity is 6 kA Icn at 380–415 V AC, 50 Hz, conforming to EN/IEC 61009-2-1, and 6 kA Icu per EN/IEC 60947-2."},{"question":"What compliance documentation does Schneider provide for A9D97420?","answer":"The part carries EN/IEC 60947-2 and EN/IEC 61009-2-1 certification, plus quality marks from NF, IMQ, VDE, and KEMA-KEUR. Overvoltage category III per IEC 60364. RoHS and REACH compliance are standard for the Acti9 range."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9D97420","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9D97420 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}