{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9DC2606","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9DC2606","canonicalUrl":"https://aoctrl.com/schneider/A9DC2606","factsUrl":"https://aoctrl.com/api/mcp/products/A9DC2606","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iCV40 RCBO, A9DC2606, 1P+N, 6 A, C-curve, 30 mA earth leakage, 4500 A breaking capacity.","salesMarkdown":"Rated at 6 A with a C-curve magnetic trip (5 to 10 x In) and integrated 30 mA earth-leakage sensitivity, it handles final-circuit protection for lighting, socket outlets, and small loads on 230 V AC networks. The 6 A rated current (In) governs the continuous load the RCBO can carry without tripping thermally — sized for a 1.5 mm² or 2.5 mm² final subcircuit, not a feeder. The C-curve (5 to 10 x In) means magnetic tripping occurs between 30 A and 60 A, which suits circuits with moderate inrush like small motors or fluorescent ballasts; a B-curve would trip faster on those loads, a D-curve slower. The 30 mA earth-leakage threshold provides personnel protection (30 mA is the standard for shock risk per IEC 60364) and is integrated into the same 36 mm wide module — no separate RCCB needed upstream for that branch. The thermal-magnetic trip technology is the standard dual-element approach — thermal bimetal for overload, solenoid for short-circuit. Neutral on the left, phase on the right — the 9 mm connection pitch between phase and neutral matches standard Acti9 busbar spacing. Tunnel terminals accept 1 to 16 mm² rigid or 1 to 10 mm² flexible; strip length 14 mm, torque to 2 N·m. IP20 on the body (finger-safe), IP40 inside the modular enclosure — fine for a distribution board, not for washdown.","metaTitle":"Schneider Electric A9DC2606 Acti9 iCV40 RCBO, 6A C-Curve 30m","metaDescription":"Schneider Electric A9DC2606 Acti9 iCV40 RCBO, 6 A rated, C-curve, 30 mA earth leakage, 4500 A breaking capacity. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iCV40","Mounting mode":"Clip-on","Quality labels":"VDE KEMA-KEUR","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"Fault indication ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"4500 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Device short name":"iCV40","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"6 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device Sealable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 4500 A at 230 V AC 50/60 Hz conforming to EN 61009-2-1 Idm 500 A at 230 V AC 50/60 Hz conforming to IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"4500 A 100 % x Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: tooth"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$220.10","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/A9DC2606/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40-1p+n-6a-c-curve-4500a-a-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9DC2606/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9DC2606?","answer":"Submit an RFQ through this listing. The part is sourced to order via independent distribution; current pricing and stock levels are confirmed at quote time."},{"question":"What is the closest alternative to A9DC2606 in the Acti9 family?","answer":"Within the Acti9 iCV40 range, the key variant differences are rated current (In) and earth-leakage sensitivity. The A9DC2606 is a 6 A, 30 mA unit. A higher-current sibling like the A9DC2620 (20 A, 30 mA) shares the same 1P+N format, C-curve, and 4500 A breaking capacity — the choice depends on the load current of the protected circuit."},{"question":"What compliance documentation does Schneider provide for A9DC2606?","answer":"The A9DC2606 carries VDE and KEMA-KEUR quality labels and is certified to EN/IEC 61009-2-1. Standard Schneider declarations of conformity cover CE marking; RoHS and REACH compliance documentation is available on request through the RFQ process."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9DC2606","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9DC2606 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}