{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9DC2616","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9DC2616","canonicalUrl":"https://aoctrl.com/schneider/A9DC2616","factsUrl":"https://aoctrl.com/api/mcp/products/A9DC2616","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iCV40 RCBO, 1P+N, 16 A, C-curve, 30 mA earth leakage, 4.5 kA breaking capacity, DIN rail mount.","salesMarkdown":"It protects a final subcircuit against overload, short-circuit (thermal-magnetic trip, C-curve, magnetic tripping limit 5...10 x In), and earth leakage at 30 mA sensitivity, all in one 36 mm wide DIN-rail package. Rated 16 A (In) with a C-curve — so it holds up to 16 A continuous load and trips magnetically between 5 and 10 times that (80–160 A) for short-circuit protection. Breaking capacity is 4.5 kA Icn at 230 V AC, 50/60 Hz, per EN/IEC 61009-2-1. Earth-leakage protection is integrated at 30 mA sensitivity — that is the standard threshold for personal protection against indirect contact (touch voltage) per IEC 60364. It covers the same circuit as the overcurrent protection, so no separate RCCB module needed. Neutral is on the left, phase on the right — wire it accordingly. Tunnel terminals accept 1...16 mm² rigid or 1...10 mm² flexible; strip 14 mm, torque to 2 N.m. IP20 rated (finger-safe terminals), IP40 in a modular enclosure. Pollution degree 3, overvoltage category III — suitable for fixed installations inside a distribution board.","metaTitle":"Schneider Electric A9DC2616 Acti9 iCV40 RCBO, 16 A, 30 mA, C","metaDescription":"Schneider Electric A9DC2616 Acti9 iCV40 RCBO, 16 A rated, 30 mA earth leakage, C-curve, 4.5 kA breaking capacity, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iCV40","Mounting mode":"Clip-on","Quality labels":"KEMA-KEUR VDE","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON/OFF indication Fault indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"4500 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Device short name":"iCV40","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"16 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Sealable Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 4500 A at 230 V AC 50/60 Hz conforming to EN 61009-2-1 Idm 500 A at 230 V AC 50/60 Hz conforming to IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"4500 A 100 % x Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: tooth"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$183.71","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/A9DC2616/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40-1p+n-16a-c-curve-4500a-a-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9DC2616/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the A9DC2616 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What are the key ratings of the A9DC2616?","answer":"16 A rated current, C-curve, 30 mA earth-leakage sensitivity, 4.5 kA breaking capacity at 230 V AC, 1P+N, DIN rail mount, thermal-magnetic trip."},{"question":"What compliance documentation does Schneider provide for the A9DC2616?","answer":"The device is certified to EN/IEC 61009-2-1 and carries KEMA-KEUR and VDE quality labels. It meets the standards for fixed electrical installations per IEC 60364 (overvoltage category III, pollution degree 3)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9DC2616","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9DC2616 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}