{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9DC3713","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9DC3713","canonicalUrl":"https://aoctrl.com/schneider/A9DC3713","factsUrl":"https://aoctrl.com/api/mcp/products/A9DC3713","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iCV40 RCBO, 13 A, 30 mA earth-leakage, C-curve, 3P+N, 6 kA Icn at 400 V AC, DIN rail mount, thermal-magnetic trip.","salesMarkdown":"The Schneider Electric A9DC3713 is an Acti9 iCV40 RCBO — a combined residual-current circuit breaker with overcurrent protection, rated 13 A with 30 mA earth-leakage sensitivity, C-curve, 3P+N poles, and a breaking capacity of 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1. Tunnel-type terminals accept 1…16 mm² rigid or 1…10 mm² flexible cable; tighten to 2 N·m. IP20 rated (IP40 in modular enclosure), so it suits enclosed distribution boards — not outdoor or washdown locations. Rated for 20000 electrical and 20000 mechanical cycles. Pollution degree 3, overvoltage category III per IEC 60364, operating altitude up to 2000 m, relative humidity 95 % at 55 °C.","metaTitle":"Schneider Electric A9DC3713 Acti9 iCV40 RCBO, 13 A, 30 mA, C","metaDescription":"Schneider Electric A9DC3713 Acti9 iCV40 RCBO, 13 A rated, 30 mA earth-leakage, C-curve, 3P+N, 6 kA breaking capacity at 400 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"90 mm","Colour":"White","Height":"93 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"10","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iCV40","Mounting mode":"Clip-on","Quality labels":"VDE EAC","lifecycle_stage":"current","Connection pitch":"18 mm between phases 9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON/OFF indication Fault indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Device short name":"iCV40N","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"13 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"3","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device Sealable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-1","[Ui] rated insulation voltage":"440 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"400 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 3000 A at 400 V AC 50/60 Hz conforming to EN 61009-2-1 Idm 500 A at 400 V AC 50/60 Hz conforming to IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: tooth"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/il/en/product/A9DC3713/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40-3p+n-13-a-c-curve-6000-a-30-ma-a-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9DC3713/alternatives.json"},"ai":{"faq":[{"question":"What is A9DC3713 used for?","answer":"The A9DC3713 is a combined RCBO (residual-current circuit breaker with overcurrent protection) used as an outgoer in distribution boards to protect final circuits against overloads, short-circuits, and earth faults."},{"question":"What are the key ratings of A9DC3713?","answer":"Rated current 13 A, earth-leakage sensitivity 30 mA, C-curve (magnetic trip 5–10× In), breaking capacity 6000 A Icn at 400 V AC, 3P+N poles, thermal-magnetic trip."},{"question":"Where can I buy A9DC3713?","answer":"The A9DC3713 is sourced and quoted to order against an RFQ through independent distribution; current pricing and availability are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9DC3713","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9DC3713 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}