{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9DC4710","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9DC4710","canonicalUrl":"https://aoctrl.com/schneider/A9DC4710","factsUrl":"https://aoctrl.com/api/mcp/products/A9DC4710","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iCV40H RCBO, A9DC4710, 3P+N, 10 A rated, C-curve, 30 mA earth-leakage, 10 kA breaking capacity at 400 V AC, thermal-magnetic trip, DIN rail mount.","salesMarkdown":"The Schneider Electric A9DC4710 is an Acti9 iCV40H RCBO — a combined residual-current circuit breaker with overcurrent protection, 3 poles plus neutral, rated 10 A with a C-curve magnetic trip (5 to 10 x In). It integrates earth-leakage protection at 30 mA sensitivity, so one device covers both overcurrent and ground-fault protection on the outgoing circuit. Limitation class 3 per the same standard keeps let-through energy low, which helps with downstream device coordination. The 9 mm connection pitch between phase and neutral matches the standard Acti9 modular spacing — 10 modules wide (90 mm). The 30 mA earth-leakage threshold is the standard sensitivity for personal protection against indirect contact. The C-curve (5 to 10 x In magnetic trip) suits loads with moderate inrush. Mechanical and electrical durability both rated at 20,000 cycles, which is typical for a distribution-grade RCBO — not a switching device for frequent load making/breaking, but fine for protection duty with occasional manual operation. Neutral is on the left (fixed position), so busbar and wiring order matters when replacing an existing unit in a multi-row board. The toggle control gives clear ON/OFF and fault-indication status through the front window.","metaTitle":"Schneider Electric A9DC4710 Acti9 iCV40 RCBO, 10 A, 30 mA, 1","metaDescription":"Schneider Electric A9DC4710 Acti9 iCV40H RCBO: 10 A rated, 30 mA earth leakage, 10 kA breaking capacity at 400 V AC, C-curve, 3P+N. Current production, sourced to order. Request qu","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"90 mm","Colour":"White","Height":"93 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"10","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iCV40","Mounting mode":"Clip-on","lifecycle_stage":"current","Connection pitch":"18 mm between phases 9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"Fault indication ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Device short name":"iCV40H","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"10 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"3","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Sealable Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-1","[Ui] rated insulation voltage":"440 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"400 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 3000 A at 400 V AC 50/60 Hz conforming to EN 61009-2-1 Idm 500 A at 400 V AC 50/60 Hz conforming to IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: tooth"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$261.47","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/A9DC4710/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40h-3p+n-10a-c-curve-10000a-a-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9DC4710/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9DC4710","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9DC4710 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}