{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9DC6906","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9DC6906","canonicalUrl":"https://aoctrl.com/schneider/A9DC6906","factsUrl":"https://aoctrl.com/api/mcp/products/A9DC6906","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60 RCBO, 3P+N, C-curve, 6 A rated current, 30 mA earth-leakage sensitivity, 6 kA breaking capacity at 400/415 V, clip-on DIN rail mount, white.","salesMarkdown":"The Schneider Electric A9DC6906 is a 3-pole + neutral residual current breaker with overcurrent protection (RCBO) from the Acti9 iC60 series. It combines a C-curve thermal-magnetic MCB (6 A rated at 30 °C) with integrated 30 mA earth-leakage protection in a single 54 mm wide module that clips onto a DIN rail. Rated breaking capacity is 6 kA Icn at 400/415 V AC — sufficient for most residential and light commercial final subcircuits in TN earthing systems. The C-curve characteristic means the magnetic trip operates between 5 and 10 times In (30–60 A), suited for inductive loads like small motors or fluorescent lighting where inrush is moderate. Clip-on mounting to standard DIN rail. The module occupies 6 x 9 mm pitches (54 mm width). Depth is 77.2 mm, height 112 mm. Wire stripping length is 11 mm for bottom connections. Tightening torque for the power circuit is 2.5 N.m. Mechanical durability is rated at 20,000 cycles; electrical durability at 5,000 cycles under rated load. Limitation class 3 indicates energy-limiting performance that reduces let-through energy during short circuits.","metaTitle":"Schneider Electric A9DC6906 Acti9 iC60 RCBO, C-curve 6 A, 30","metaDescription":"Schneider Electric A9DC6906 Acti9 iC60 RCBO, 3P+N, C-curve, 6 A rated, 30 mA earth leakage, 6 kA breaking capacity at 400/415 V. Current lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77.2 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"112 mm","Standards":"AS/NZS 61009.1","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Grid distance":"45 mm","Mounting mode":"Clip-on","Surge current":"250 A","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"6000 A Icn at 400/415 V","Device short name":"iC60N3 RCBO","Network frequency":"50/60 Hz","Poles description":"3P + Ns","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 2.5 N.m top","[In] rated current":"6 A at 30 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 11 mm for bottom connection","Connections - terminals":"Screw clamp terminal (top) 1...25 mm² rigid without cable end","IP degree of protection":"IP20","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"3","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to IEC 61009-1","Circuit breaker application":"Distribution","Locking options description":"Handle sealable with cable diameter 1.4mm in OFF or ON position","Test button operating voltage":"260...457 V","[Ui] rated insulation voltage":"500 V","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"400/415 V","Ambient air temperature for storage":"-25...70 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"YES","Operating voltage for protection against earth-leakage":"150...457 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/au/en/product/A9DC6906/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ic60-rcbo-3p+ns-c-curve-6a-30ma-a-type-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9DC6906/alternatives.json"},"ai":{"faq":[{"question":"What is the earth-leakage sensitivity of A9DC6906?","answer":"The integrated earth-leakage protection is set at 30 mA sensitivity."},{"question":"What standards does A9DC6906 comply with?","answer":"The A9DC6906 is certified to AS/NZS 61009.1, the Australian/New Zealand standard for RCBOs."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9DC6906","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9DC6906 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}