{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9DC6916","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9DC6916","canonicalUrl":"https://aoctrl.com/schneider/A9DC6916","factsUrl":"https://aoctrl.com/api/mcp/products/A9DC6916","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60 RCBO, 3P + Ns, 16 A rated current at 30 °C, C-curve, 30 mA earth-leakage sensitivity, 6 kA Icn breaking capacity at 400/415 V.","salesMarkdown":"The 30 mA earth-leakage sensitivity covers personnel protection per AS/NZS 61009.1. Limitation class 3 (energy-limiting) means it clears a fault fast enough to restrict let-through energy, which helps with downstream device coordination and reduces arc-flash risk on the panel side. Clip-on mounting to a 45 mm grid DIN rail, standard for European-style distribution boards. Occupies 6 x 9 mm pitches (54 mm wide), 112 mm tall, 77.2 mm deep — fits a standard 4-module slot in a residential or light-commercial consumer unit. IP20 rated, so it belongs inside a closed enclosure, not in a washdown area. Padlockable with a 4 mm hasp for lockout/tagout. ON/OFF indicator on the toggle gives a visible state check without opening the cover. Tropicalisation class 2 means it's treated for damp-heat environments up to 95% RH at 55 °C — relevant for coastal or unconditioned plant rooms.","metaTitle":"Schneider Electric A9DC6916 Acti9 iC60 RCBO, 16 A C-curve, 3","metaDescription":"Schneider Electric A9DC6916 Acti9 iC60 RCBO, 16 A rated current, C-curve, 30 mA earth-leakage sensitivity, 6 kA breaking capacity at 400/415 V. Sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77.2 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"112 mm","Standards":"AS/NZS 61009.1","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Grid distance":"45 mm","Mounting mode":"Clip-on","Surge current":"250 A","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"6000 A Icn at 400/415 V","Device short name":"iC60N3 RCBO","Network frequency":"50/60 Hz","Poles description":"3P + Ns","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 2.5 N.m top","[In] rated current":"16 A at 30 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 11 mm for bottom connection","Connections - terminals":"Screw clamp terminal (top) 1...25 mm² rigid without cable end","IP degree of protection":"IP20","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"3","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to IEC 61009-1","Circuit breaker application":"Distribution","Locking options description":"Handle sealable with cable diameter 1.4mm in OFF or ON position","Test button operating voltage":"260...457 V","[Ui] rated insulation voltage":"500 V","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"400/415 V","Ambient air temperature for storage":"-25...70 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"YES","Operating voltage for protection against earth-leakage":"150...457 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/au/en/product/A9DC6916/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ic60-rcbo-3p+ns-c-curve-16a-30ma-a-type-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9DC6916/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9DC6916?","answer":"6000 A Icn at 400/415 V, which is the standard fault-interruption rating for this class of RCBO in residential and light-commercial distribution boards."},{"question":"What is the A9DC6916 used for?","answer":"It's a combined residual current breaker with overcurrent protection (RCBO) for a 3-phase outgoer circuit. It protects against earth leakage (30 mA sensitivity) and overcurrent/short-circuit (16 A, C-curve) in a single DIN-rail module."},{"question":"Where can I buy the A9DC6916?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quotation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9DC6916","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9DC6916 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}