{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9DC6925","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9DC6925","canonicalUrl":"https://aoctrl.com/schneider/A9DC6925","factsUrl":"https://aoctrl.com/api/mcp/products/A9DC6925","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60 RCBO, 3P + Ns, 25 A rated current, 30 mA earth-leakage sensitivity, 6 kA breaking capacity at 400/415 V, C-curve, thermal-magnetic trip, DIN-rail clip-on.","salesMarkdown":"The Schneider Electric A9DC6925 is a 3P + Ns Acti9 iC60 RCBO — a combined residual current breaker with overcurrent protection (RCBO) — rated 25 A at 30 °C with an integrated 30 mA earth-leakage sensitivity. Its 6 kA breaking capacity (Icn at 400/415 V) and C-curve thermal-magnetic trip make it a standard choice for final subcircuit protection in TN earthing systems on 50/60 Hz AC networks. The 6 kA Icn at 400/415 V means this RCBO safely interrupts a fault current up to 6 kA without welding its contacts or failing to clear — that is the standard domestic and light-commercial fault level under AS/NZS 61009.1, so it is sized for most distribution boards downstream of a higher-rated upstream device. The 30 mA earth-leakage sensitivity provides additional protection against electric shock for people and equipment, meeting typical socket-outlet and lighting circuit requirements in residential and commercial installations. Clip-on mounting to standard DIN rail (35 mm). The device occupies 6 x 9 mm pitches (54 mm width) and fits a 45 mm grid distance. Dimensions: 112 mm height, 77.2 mm depth. Tightening torque 2.5 N·m for the power circuit. Neutral position is left; padlockable with a Ø 4 mm padlock for lockout/tagout. Standards compliance: AS/NZS 61009.1 (Australian/New Zealand standard for RCBOs). Tropicalisation class 2, relative humidity 95% at 55 °C. Electrical durability 5000 cycles, mechanical durability 20000 cycles. Limitation class 3.","metaTitle":"Schneider Electric A9DC6925 Acti9 iC60 RCBO, 25 A, 30 mA, 6","metaDescription":"Schneider Electric A9DC6925 Acti9 iC60 RCBO, 25 A rated current, 30 mA earth-leakage sensitivity, 6 kA breaking capacity at 400/415 V. Current lifecycle stage. Available to order a","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77.2 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"112 mm","Standards":"AS/NZS 61009.1","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Grid distance":"45 mm","Mounting mode":"Clip-on","Surge current":"250 A","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"6000 A Icn at 400/415 V","Device short name":"iC60N3 RCBO","Network frequency":"50/60 Hz","Poles description":"3P + Ns","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 2.5 N.m top","[In] rated current":"25 A at 30 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 11 mm for bottom connection","Connections - terminals":"Screw clamp terminal (top) 1...25 mm² rigid without cable end","IP degree of protection":"IP20","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"3","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to IEC 61009-1","Circuit breaker application":"Distribution","Locking options description":"Handle sealable with cable diameter 1.4mm in OFF or ON position","Test button operating voltage":"260...457 V","[Ui] rated insulation voltage":"500 V","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"400/415 V","Ambient air temperature for storage":"-25...70 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"YES","Operating voltage for protection against earth-leakage":"150...457 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/au/en/product/A9DC6925/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ic60-rcbo-3p+ns-c-curve-25a-30ma-a-type-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9DC6925/alternatives.json"},"ai":{"faq":[{"question":"What is A9DC6925's listed depth?","answer":"The A9DC6925 has a depth of 77.2 mm."},{"question":"What is A9DC6925's listed range?","answer":"The A9DC6925 belongs to the Acti9 range from Schneider Electric."},{"question":"What compliance documentation does this brand provide for A9DC6925?","answer":"The A9DC6925 complies with AS/NZS 61009.1. For RoHS, REACH, or other documentation, request it with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9DC6925","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9DC6925 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}