{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9DC6950","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9DC6950","canonicalUrl":"https://aoctrl.com/schneider/A9DC6950","factsUrl":"https://aoctrl.com/api/mcp/products/A9DC6950","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60 RCBO, 3P + Ns, 50 A rated current at 30 °C, C-curve, 30 mA earth-leakage sensitivity, 6 kA breaking capacity at 400/415 V, clip-on DIN rail mount.","salesMarkdown":"It protects a 3-phase + neutral outgoing circuit against overloads, short-circuits, and earth leakage in a single 54 mm wide package. Breaking capacity is 6 kA Icn at 400/415 V AC, 50/60 Hz, which covers most commercial and light industrial distribution boards where the prospective fault current stays below that level. The limitation class 3 rating means it lets through less energy during a fault, helping downstream selectivity. Clip-on mounting to standard 35 mm DIN rail. The 54 mm width occupies 6 modules of 9 mm pitch. Depth is 77.2 mm, height 112 mm — fits standard distribution enclosures without crowding the door or busbar shroud. Tightening torque is 2.5 N.m. Wire strip length is 11 mm for bottom connections. Neutral is on the left, and the toggle provides local ON/OFF indication. Padlockable with a Ø 4 mm padlock for lockout/tagout during maintenance. Designed and certified to AS/NZS 61009.1, the Australia/New Zealand standard for RCBOs. Suitable for TN earthing systems. Tropicalisation level 2 indicates treatment against humidity and corrosion for warm, damp environments. Relative humidity tolerance of 95% at 55 °C covers most non-condensing indoor installations.","metaTitle":"Schneider Electric A9DC6950 Acti9 iC60 RCBO, 50 A C-curve, 3","metaDescription":"Schneider Electric A9DC6950 Acti9 iC60 RCBO, 50 A rated current, C-curve, 30 mA earth-leakage, 6 kA breaking capacity at 400/415 V. Active production, clip-on DIN rail. Quoted to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77.2 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"112 mm","Standards":"AS/NZS 61009.1","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60 RCBO","Grid distance":"45 mm","Mounting mode":"Clip-on","Surge current":"250 A","Earthing system":"TN","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Breaking capacity":"6000 A Icn at 400/415 V","Device short name":"iC60N3 RCBO","Network frequency":"50/60 Hz","Poles description":"3P + Ns","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 2.5 N.m top","[In] rated current":"50 A at 30 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 11 mm for bottom connection","Connections - terminals":"Screw clamp terminal (top) 1...25 mm² rigid without cable end","IP degree of protection":"IP20","Earth-leakage protection":"Integrated","Provision for padlocking":"Padlockable with padlock Ø 4 mm","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"3","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to IEC 61009-1","Circuit breaker application":"Distribution","Locking options description":"Handle sealable with cable diameter 1.4mm in OFF or ON position","Test button operating voltage":"260...457 V","[Ui] rated insulation voltage":"500 V","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"400/415 V","Ambient air temperature for storage":"-25...70 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage dependent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A","[Uimp] rated impulse withstand voltage":"4 kV","[Icw] rated short-time withstand current":"Icw: 250 A during 8/20 µs impulse withstand","Comb busbar and distribution block compatibility":"YES","Operating voltage for protection against earth-leakage":"150...457 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/au/en/product/A9DC6950/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ic60-rcbo-3p+ns-c-curve-50a-30ma-a-type-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9DC6950/alternatives.json"},"ai":{"faq":[{"question":"What is the earth-leakage sensitivity of this RCBO?","answer":"The integrated earth-leakage protection trips at 30 mA sensitivity. This is the standard threshold for personal protection against direct contact with live parts."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9DC6950","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9DC6950 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}