{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9DC7710","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9DC7710","canonicalUrl":"https://aoctrl.com/schneider/A9DC7710","factsUrl":"https://aoctrl.com/api/mcp/products/A9DC7710","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iCV40 RCBO, A9DC7710, 10 A, C-curve, 30 mA earth leakage, 3P+N, 6 kA breaking capacity, DIN rail mount, white.","salesMarkdown":"The Schneider Electric A9DC7710 is an Acti9 iCV40 RCBO — a combined residual-current circuit breaker with overcurrent protection, rated 10 A with a C-curve magnetic trip characteristic (5...10 x In) and integrated 300 mA earth-leakage sensitivity. It protects a 3P+N outgoing circuit against overload, short-circuit, and earth faults in one 4-module-wide (72 mm) DIN-rail unit, saving panel space over separate MCB+RCCB. The 10 A rated current (In) and C-curve mean the breaker holds 10 A indefinitely and trips magnetically between 50 A and 100 A — suited for general-purpose loads like lighting banks, small motor circuits, and socket outlets where inrush is moderate. The 300 mA earth-leakage threshold is a protection against fire risk from persistent leakage, not personnel shock (that needs 30 mA or lower); it's common on distribution outgoers feeding sub-distribution boards or fixed equipment where nuisance tripping from capacitive leakage must be avoided. Limitation class 3 (energy let-through) means it restricts the peak let-through energy under fault — helps with downstream coordination and reduces stress on cables and connected equipment. Clip-on mounting on a DIN rail — 9 mm pitch, 10 pitches wide (90 mm). Neutral is on the left (3P+N). Connection pitch is 18 mm between phases, 9 mm between phase and neutral. Tunnel terminals accept 1...16 mm² rigid or 1...10 mm² flexible cable; strip 14 mm and torque to 2 N.m. The toggle control gives clear ON/OFF and fault indication on the front face.","metaTitle":"Schneider Electric A9DC7710 Acti9 iCV40 10A RCBO, 30mA, C-Cu","metaDescription":"Schneider Electric A9DC7710 Acti9 iCV40 10A RCBO, 30mA earth leakage, C-curve, 6kA breaking capacity, 3P+N, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"90 mm","Colour":"White","Height":"93 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"10","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iCV40","Mounting mode":"Clip-on","Quality labels":"EAC VDE","lifecycle_stage":"current","Connection pitch":"18 mm between phases 9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"Fault indication ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Device short name":"iCV40N","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"10 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Number of protected poles":"3","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Sealable Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-1","[Ui] rated insulation voltage":"440 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"400 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 3000 A at 400 V AC 50/60 Hz conforming to EN 61009-2-1 Idm 500 A at 400 V AC 50/60 Hz conforming to IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: tooth"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$237.28","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/A9DC7710/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40n-3p+n-10a-c-curve-6000a-a-type-300ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9DC7710/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the A9DC7710 and get a price?","answer":"The A9DC7710 is sourced to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing."},{"question":"What is the A9DC7710's breaking capacity?","answer":"The A9DC7710 has a breaking capacity of 6 kA Icn at 400 V AC 50/60 Hz, conforming to EN/IEC 61009-2-1."},{"question":"What is the earth-leakage sensitivity of the A9DC7710?","answer":"The integrated earth-leakage protection is set at 300 mA sensitivity."},{"question":"What compliance documentation is available for the A9DC7710?","answer":"The A9DC7710 carries EAC and VDE quality labels and conforms to EN/IEC 61009-2-1. It is designed for pollution degree 3 and overvoltage category III per IEC 60364."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9DC7710","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9DC7710 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}