{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9DC7732","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9DC7732","canonicalUrl":"https://aoctrl.com/schneider/A9DC7732","factsUrl":"https://aoctrl.com/api/mcp/products/A9DC7732","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iCV40N RCBO, 3P+N, 32 A, C-curve, 6 kA Icn at 400 V AC, integrated 300 mA earth-leakage, thermal-magnetic trip, DIN rail mount.","salesMarkdown":"Rated 32 A with a C-curve magnetic trip (5...10 x In) and a 6 kA Icn breaking capacity at 400 V AC, it integrates 300 mA earth-leakage protection in a single 3P+N module. The thermal-magnetic trip unit handles both overload and short-circuit; the integrated RCD covers ground faults. The 32 A rated current and C-curve (5–10 x In magnetic trip) suit it for mixed resistive and moderate-inductive loads — lighting banks, small motor circuits, socket outlets. Limitation class 3 (energy let-through) helps with downstream coordination. The 300 mA earth-leakage sensitivity is a standard for general distribution, not personal shock protection (30 mA would be required for that). The 3P+N configuration with neutral on the left is fixed — verify busbar and panel layout before specifying. The 18 mm phase-to-phase pitch and 9 mm phase-to-neutral pitch match standard Acti9 distribution boards. Clip-on DIN-rail mounting (EN 60715) and tunnel terminals accepting 1...16 mm² rigid or 1...10 mm² flexible wire simplify panel assembly. Designed to EN/IEC 61009-2-1 (RCBO standard). Carries VDE and EAC quality marks. IP20 on the terminals, IP40 on the modular enclosure.","metaTitle":"Schneider Electric A9DC7732 Acti9 iCV40 RCBO, 32 A C-curve,","metaDescription":"Schneider Electric A9DC7732 Acti9 iCV40N RCBO. 32 A rated, C-curve, 6 kA breaking capacity at 400 V AC. Integrated 300 mA earth-leakage. 3P+N. Current production. Available to orde","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"90 mm","Colour":"White","Height":"93 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"10","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iCV40","Mounting mode":"Clip-on","Quality labels":"VDE EAC","lifecycle_stage":"current","Connection pitch":"18 mm between phases 9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"Fault indication ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Device short name":"iCV40N","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"32 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Number of protected poles":"3","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Sealable Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-1","[Ui] rated insulation voltage":"440 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"400 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 3000 A at 400 V AC 50/60 Hz conforming to EN 61009-2-1 Idm 500 A at 400 V AC 50/60 Hz conforming to IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: tooth"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/uk/en/product/A9DC7732/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40n-3p+n-32a-c-curve-6000a-a-type-300ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9DC7732/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9DC7732 and get a price?","answer":"The A9DC7732 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of A9DC7732?","answer":"The A9DC7732 has a 6 kA Icn breaking capacity at 400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1."},{"question":"What earth-leakage sensitivity does the A9DC7732 have?","answer":"The A9DC7732 has integrated earth-leakage protection with a sensitivity of 300 mA."},{"question":"What compliance documentation does Schneider provide for A9DC7732?","answer":"The A9DC7732 complies with EN/IEC 61009-2-1 and carries VDE and EAC quality marks. Pollution degree 3 and overvoltage category III per IEC 60364 are specified."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9DC7732","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9DC7732 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}