{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9DC8610","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9DC8610","canonicalUrl":"https://aoctrl.com/schneider/A9DC8610","factsUrl":"https://aoctrl.com/api/mcp/products/A9DC8610","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iCV40H RCBO, 1P+N, 10 A, C curve, 10 kA Icn at 230 V AC, 300 mA earth-leakage sensitivity, clip-on DIN-rail mount.","salesMarkdown":"The Schneider Electric A9DC8610 is an Acti9 iCV40H combined residual-current circuit breaker (RCBO) — one module wide, 1P+N, rated 10 A with a C curve. It integrates overcurrent protection (thermal-magnetic trip) and earth-leakage protection at 300 mA sensitivity into a single DIN-rail unit. The 10 A rated current (In) sets the continuous load capacity; the C curve (magnetic trip 5–10 x In) tolerates moderate inrush from motor or lighting loads. The 300 mA earth-leakage threshold is for equipment protection, not personnel. Clip-on mount to standard DIN rail. Neutral is on the left, phase on the right. Tunnel terminals accept 1–16 mm² rigid or 1–10 mm² flexible; strip 14 mm, torque to 2 N·m. Listed as current production. The Acti9 range is Schneider's standard modular DIN-rail family; the iCV40H variant is a common RCBO for distribution outgoing circuits.","metaTitle":"Schneider Electric A9DC8610 Acti9 iCV40H RCBO, 10 A, C Curve","metaDescription":"Schneider Electric A9DC8610 Acti9 iCV40H RCBO, 10 A rated current, C curve, 10 kA breaking capacity at 230 V AC, 300 mA earth-leakage protection. Active lifecycle, sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iCV40","Mounting mode":"Clip-on","Quality labels":"VDE EAC","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON/OFF indication Fault indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Device short name":"iCV40H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"10 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Sealable Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-1","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 6000 A at 230 V AC 50/60 Hz conforming to EN 61009-2-1 Idm 500 A at 230 V AC 50/60 Hz conforming to IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: tooth"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/hk/en/product/A9DC8610/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40h-1p+n-10a-c-curve-10000a-a-type-300ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9DC8610/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9DC8610?","answer":"10,000 A Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1. That is the rated short-circuit breaking capacity for this RCBO."},{"question":"What earth-leakage sensitivity does the A9DC8610 have?","answer":"300 mA — an equipment-protection threshold, not personnel protection. Suitable for circuits with higher expected ground-fault currents, like appliances or fixed machinery."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9DC8610","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9DC8610 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}