{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9DE3706","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9DE3706","canonicalUrl":"https://aoctrl.com/schneider/A9DE3706","factsUrl":"https://aoctrl.com/api/mcp/products/A9DE3706","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iCV40 RCBO, A9DE3706, 3P+N, 6 A rated, 30 mA earth leakage, curve C, 6 kA breaking capacity at 400 V AC, thermal-magnetic trip, DIN rail mount.","salesMarkdown":"The A9DE3706 is a 3P+N RCBO (residual current circuit breaker with overcurrent protection) from the Acti9 iCV40 series, combining a 6 A thermal-magnetic MCB with integrated 30 mA earth-leakage protection in a single DIN-rail module. The 6 A rated current and curve C (magnetic trip 5–10 × In) suit it for protecting final sub-circuits feeding resistive and light inductive loads — lighting, small appliances, control transformers — where the inrush is moderate and the steady draw stays under 6 A. The 30 mA sensitivity covers personnel protection against direct contact (30 mA is the standard threshold for shock protection per IEC 60364). Breaking capacity is 6 kA Icn at 400 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1. Limitation class 3 (energy-limiting) means the device clears a fault fast enough to restrict let-through energy, reducing stress on downstream wiring and loads. Rated for overvoltage category III (IEC 60364) and pollution degree 3, so it is suitable for fixed installations inside a distribution board where the environment is not climate-controlled but not directly exposed to rain or condensation. IP20 on the device body, IP40 inside the modular enclosure — fine for a clean, dry panel. Clip-on mounting to DIN rail (35 mm symmetrical rail per EN 60715). The 3P+N unit occupies 10 modules of 9 mm pitch (90 mm total width), which is the standard footprint for a 3P+N RCBO in the Acti9 range. Neutral is on the left. Connection pitch is 18 mm between phases and 9 mm between phase and neutral — standard for busbar connection in Acti9 distribution boards. The 73 mm depth fits standard shallow enclosures; the toggle control provides local ON/OFF and fault indication visible through the enclosure door.","metaTitle":"Schneider Electric A9DE3706 Acti9 iCV40 6A 30mA RCBO, Curve","metaDescription":"Schneider Electric A9DE3706 Acti9 iCV40 RCBO, 6A rated, 30mA earth leakage, curve C, 6kA breaking capacity at 400V AC. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"90 mm","Colour":"White","Height":"93 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"10","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iCV40","Mounting mode":"Clip-on","Quality labels":"EAC IMQ","lifecycle_stage":"current","Connection pitch":"18 mm between phases 9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"Fault indication ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Device short name":"iCV40N","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"6 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"3","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Sealable Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-1","[Ui] rated insulation voltage":"440 V AC 50/60 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"400 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 3000 A at 400 V AC 50/60 Hz conforming to EN 61009-2-1 Idm 500 A at 400 V AC 50/60 Hz conforming to IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: tooth"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/hk/en/product/A9DE3706/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40n-3p+n-6a-c-curve-6000a-ac-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9DE3706/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9DE3706?","answer":"The breaking capacity is 6 kA Icn at 400 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1."},{"question":"What is the earth leakage sensitivity of A9DE3706?","answer":"The integrated earth-leakage protection is set at 30 mA sensitivity."},{"question":"Where can I buy A9DE3706 and get current pricing?","answer":"The A9DE3706 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9DE3706","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9DE3706 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}