{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9DF8606","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9DF8606","canonicalUrl":"https://aoctrl.com/schneider/A9DF8606","factsUrl":"https://aoctrl.com/api/mcp/products/A9DF8606","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iCV40 RCBO, 1P+N, 6 A, C-curve, 10 kA Icn at 230 V AC, 300 mA earth-leakage, thermal-magnetic trip, DIN-rail clip-on, IP20/IP40.","salesMarkdown":"The Schneider Electric A9DF8606 is an Acti9 iCV40 residual-current circuit breaker with overcurrent protection (RCBO) — a single module that combines a 6 A thermal-magnetic MCB with a 300 mA earth-leakage detector. It protects final circuits against overload, short-circuit (C-curve, magnetic trip 5–10 × In), and ground faults, all in one 36 mm-wide, 1P+N package that clips onto a DIN rail. The C-curve means it holds through moderate inrush (motors, transformers, LED drivers) and trips fast on hard shorts. The 300 mA earth-leakage threshold is a ground-fault level for fixed equipment. Thermal-magnetic trip means the bimetal handles sustained overloads (slow, heat-based) and the solenoid handles short-circuits (instantaneous above 5–10 × In). Tunnel terminals accept 1–16 mm² rigid or 1–10 mm² flexible cable; tighten to 2 N·m. The Acti9 family is Schneider's active residential and light-commercial distribution range.","metaTitle":"Schneider Electric A9DF8606 Acti9 iCV40 RCBO, 6 A, C-curve,","metaDescription":"Schneider Electric A9DF8606 Acti9 iCV40 RCBO, 6 A rated, C-curve, 10 kA breaking capacity, 300 mA earth-leakage. Current production, DIN-rail mount. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iCV40","Mounting mode":"Clip-on","Quality labels":"EAC VDE","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"Fault indication ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Device short name":"iCV40H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"6 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Sealable Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 6000 A at 230 V AC 50/60 Hz conforming to EN 61009-2-1 Idm 500 A at 230 V AC 50/60 Hz conforming to IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: tooth"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/A9DF8606/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40h-1p+n-6a-c-curve-10000a-asi-type-300ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9DF8606/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9DF8606?","answer":"The A9DF8606 has a breaking capacity of 10,000 A Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9DF8606","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9DF8606 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}