{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9DG2616","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9DG2616","canonicalUrl":"https://aoctrl.com/schneider/A9DG2616","factsUrl":"https://aoctrl.com/api/mcp/products/A9DG2616","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iCV40 RCBO, 1P+N, 16 A, 30 mA, B-curve, 4500 A, DIN rail.","salesMarkdown":"The Schneider Electric A9DG2616 is an Acti9 iCV40 RCBO — a combined residual-current circuit breaker with overcurrent protection in a single 36 mm-wide, 1P+N module. Breaking capacity is 4500 A Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1. The 16 A rated current (In) sets the continuous load limit for the outgoing circuit — size your downstream conductors and loads to stay under this. The 30 mA earth-leakage threshold provides personal protection against direct contact; it is the standard sensitivity for socket-outlet circuits in many domestic and commercial installations. The B-curve (3–5 x In magnetic trip) means the breaker will hold through mild motor inrush or capacitive loads but trips quickly on a hard short — a good match for lighting, small appliances, and general-purpose outlets where the load profile is predictable. In a distribution board, this limits where the RCBO can be placed downstream of a larger upstream breaker or fuse that clips the prospective fault current below 4.5 kA. Thermal-magnetic trip technology means the thermal element handles sustained overloads (slow, heat-dependent) while the magnetic coil reacts to short-circuit currents. The 20000-cycle electrical and mechanical endurance is typical for this class of RCBO — adequate for normal switching duty in a distribution board, but not intended for frequent load-break applications like motor starting. Tunnel-type terminals accept 1 to 16 mm² rigid or 1 to 10 mm² flexible cable; strip 14 mm and tighten to 2 N·m.","metaTitle":"Schneider Electric A9DG2616 Acti9 iCV40 RCBO, 16A, 30mA, B-C","metaDescription":"Schneider Electric A9DG2616 Acti9 iCV40 RCBO, 16 A rated current, 30 mA earth leakage, B-curve, 4500 A breaking capacity, DIN rail mount. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iCV40","Mounting mode":"Clip-on","Quality labels":"KEMA-KEUR VDE","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON/OFF indication Fault indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"4500 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Device short name":"iCV40","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"16 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device Sealable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 4500 A at 230 V AC 50/60 Hz conforming to EN 61009-2-1 Idm 500 A at 230 V AC 50/60 Hz conforming to IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"4500 A 100 % x Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: tooth"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$168.53","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/A9DG2616/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40-1p+n-16a-b-curve-4500a-a-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9DG2616/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the A9DG2616 and get a price?","answer":"The A9DG2616 is sourced and quoted to order against an RFQ through independent distribution channels. Submit an RFQ for current availability and pricing — stock levels and lead times are confirmed at quote time."},{"question":"What are the key ratings of the A9DG2616?","answer":"The A9DG2616 is a 16 A, 30 mA, B-curve RCBO with a 4500 A breaking capacity at 230 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1. It is a 1P+N module, 36 mm wide, for DIN-rail mounting."},{"question":"What compliance documentation does Schneider provide for the A9DG2616?","answer":"The A9DG2616 carries KEMA-KEUR and VDE quality labels and conforms to EN/IEC 61009-2-1. It is rated for pollution degree 3 and overvoltage category III per IEC 60364. The manufacturer typically provides a Declaration of Conformity and product-specific compliance certificates upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9DG2616","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9DG2616 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}