{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9DH3632","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9DH3632","canonicalUrl":"https://aoctrl.com/schneider/A9DH3632","factsUrl":"https://aoctrl.com/api/mcp/products/A9DH3632","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iCV40 RCBO, A9DH3632, 32 A, 30 mA, B-curve, 6 kA, 1P+N, DIN rail.","salesMarkdown":"## Active-production RCBO for distribution outgoers The A9DH3632 is a Schneider Electric Acti9 iCV40 residual-current circuit breaker with overcurrent protection (RCBO), combining a 32 A thermal-magnetic trip unit with integrated 30 mA earth-leakage protection in a single 1P+N module. Rated breaking capacity is 6 kA Icn at 230 V AC, 50/60 Hz, per EN/IEC 61009-2-1 — adequate for most residential and light commercial outgoer circuits where the prospective short-circuit current stays under that threshold. The B-curve (magnetic trip 3–5 x In) suits resistive and general-purpose loads where nuisance tripping from inrush is not a concern. The IP20 body (IP40 in modular enclosure) confirms it is designed for dry, enclosed panels only. ## Lifecycle and compliance posture EAC marking and EN/IEC 61009-2-1 conformance are documented. The part does not carry a UL listing on its spec sheet. The 73 mm depth fits standard Acti9 enclosures without protruding beyond the door. Mechanical durability is rated at 20,000 cycles, electrical at 10,000 cycles — figures typical for a distribution-grade RCBO. For an MRO planner stocking spares, this is a long-life component in normal service; replacement intervals are driven by fault events, not wear-out.","metaTitle":"A9DH3632 Acti9 iCV40 32A 30mA RCBO, 6kA, B-Curve","metaDescription":"A9DH3632 Acti9 iCV40 32A 30mA RCBO, 6kA breaking capacity, B-curve, 1P+N, DIN rail. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iCV40","Mounting mode":"Clip-on","Quality labels":"EAC","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to EN/IEC 61009-2-1","Local signalling":"ON/OFF indication Fault indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Device short name":"iCV40N","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"32 A","Overvoltage category":"III conforming to IEC 60364","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device Sealable","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"400 V AC 50/60 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 6000 A at 230 V AC 50/60 Hz conforming to EN 61009-2-1 Idm 500 A at 230 V AC 50/60 Hz conforming to IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Top or bottom: tooth"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$274.85","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/uk/en/product/A9DH3632/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-icv40-1p+n-32-a-b-curve-6000-a-30-ma-ac-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9DH3632/alternatives.json"},"ai":{"faq":[{"question":"What is A9DH3632's listed depth?","answer":"The A9DH3632 has a depth of 73 mm, which fits standard Acti9 enclosures."},{"question":"What is A9DH3632's listed range?","answer":"The A9DH3632 belongs to the Schneider Electric Acti9 range, specifically the iCV40 series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9DH3632","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9DH3632 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}