{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F03202","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F03202","canonicalUrl":"https://aoctrl.com/schneider/A9F03202","factsUrl":"https://aoctrl.com/api/mcp/products/A9F03202","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, miniature circuit breaker, A9F03202, 2 A, B-curve, 2-pole, 50 kA Icu at 220-240 V AC, DIN rail.","salesMarkdown":"The 2-pole (2P) configuration switches both line and neutral, giving full isolation on single-phase AC or DC circuits. Breaking capacity is the headline number here: 50 kA Icu at 220-240 V AC (per EN/IEC 60947-2) means this breaker can safely interrupt a fault current up to 50,000 A without welding its contacts or failing catastrophically. At 400 V AC the Icu drops to 25 kA, and under the domestic standard EN/IEC 60898-1 it's rated 6 kA Icn at 400 V — so for a commercial or industrial panel fed by a transformer with high prospective fault current, the 60947-2 rating is the one that governs coordination. Thermal-magnetic trip technology combines a bimetal strip for overload protection (time-delayed, inversely proportional to current) and a solenoid for short-circuit protection (instantaneous above the magnetic threshold). Width is 36 mm (4 x 9 mm pitches), height 91 mm, depth 78.5 mm — fits a standard distribution board or sub-panel enclosure. The double-terminal design (top or bottom) allows daisy-chaining or looping the supply without additional distribution blocks. Local trip indicator and contact position indicator give visual confirmation of state without needing to meter the load side — useful during commissioning or fault-finding when the panel door is open. Dual-rated to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/similar) — this gives flexibility in specification: the same breaker can be used in a residential consumer unit (60898-1) or an industrial panel (60947-2), with the higher breaking capacity of the latter standard governing the fault rating. Relative humidity tolerance is 95 % at 55 °C. Suitability for isolation is confirmed under both standards — the breaker can be used as a disconnecting means for safe maintenance, provided the load side is de-energised and the toggle is padlockable (check the specific padlock accessory for this frame).","metaTitle":"Schneider Electric A9F03202 Acti9 iC60N MCB, 2 A, Curve B, 2","metaDescription":"Schneider Electric A9F03202 Acti9 iC60N miniature circuit breaker, 2 A rated current, B-curve, 2-pole, 50 kA breaking capacity at 220-240 V AC. DIN rail mount, IP20. Current lifecy","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"2 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"50 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/94976a2d1f94d1bd765b6ff8433f003c.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F03202/miniature-circuit-breaker-mcb-acti9-ic60n-2p-2a-b-curve-6000a-iec-608981-50ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F03202/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9F03202?","answer":"The A9F03202 has a breaking capacity of 50 kA Icu at 220-240 V AC (per EN/IEC 60947-2), 25 kA Icu at 440 V AC, and 6 kA Icn at 400 V AC (per EN/IEC 60898-1)."},{"question":"What is the closest alternative to A9F03202?","answer":"Within the Acti9 iC60N family, the A9F03202 is a 2 A, B-curve, 2-pole variant. The closest alternative with a different rating would be a different current (e.g., 1 A or 4 A) or curve (C or D) in the same physical frame — but there is no single pin-compatible substitute for this exact order code. For a direct replacement, order the same A9F03202."},{"question":"Where can I buy A9F03202 and get current pricing?","answer":"The A9F03202 is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — stock and lead time are confirmed at quote time."},{"question":"What compliance documentation does A9F03202 carry?","answer":"The A9F03202 is certified to EN/IEC 60947-2 and EN/IEC 60898-1. It carries IP20 protection, pollution degree 3, overvoltage category IV, and tropicalisation class 2 per IEC 60068-1. For RoHS/REACH/UL documentation, refer to the manufacturer's declaration or request it with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F03202","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F03202 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}