{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F03232","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F03232","canonicalUrl":"https://aoctrl.com/schneider/A9F03232","factsUrl":"https://aoctrl.com/api/mcp/products/A9F03232","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, A9F03232, miniature circuit-breaker, 32 A, 2-pole, curve B, 36 kA Icu at 12-133 V AC, DIN rail mount, white.","salesMarkdown":"## Miniature circuit-breaker, 32 A, 2-pole, curve B The Schneider Electric A9F03232 is an Acti9 iC60N miniature circuit-breaker rated 32 A with 2 protected poles and a B tripping curve (4 x In magnetic trip, ±20 %). It carries a 36 kA Icu breaking capacity at 12–133 V AC and 20 kA Icu at 220–240 V AC, both per EN/IEC 60947-2, plus a 10 kA Icn at 400 V AC per EN/IEC 60898-1. That dual-standard rating means it can serve as a branch-circuit protective device under 60947-2 for industrial panels or as a final-subcircuit MCB under 60898-1 for distribution boards — same part, different passport. The thermal-magnetic trip unit handles overloads and short-circuits. Overvoltage category IV and pollution degree 3 ratings confirm it is designed for main panel installation, not downstream subpanels. The double terminal accepts 1–35 mm² rigid or 1–25 mm² flexible on top or bottom; strip length is 14 mm. A visible trip indicator and contact position indicator give local status without needing to remove the cover. The toggle control is manual on-off, with a separate earth-leakage block available as an add-on (not integrated). This is a standard catalogue item from Schneider Electric's Acti9 range. For volume or scheduled releases, a blanket PO with release dates typically secures better lead-time consistency.","metaTitle":"Schneider Electric A9F03232 Acti9 iC60N MCB, 32 A, 2P, Curve","metaDescription":"Schneider Electric A9F03232 Acti9 iC60N miniature circuit-breaker, 32 A, 2-pole, curve B, 36 kA breaking capacity. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"32 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a2623cea4951cc61ff00ce4b114e961e.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F03232/miniature-circuit-breaker-mcb-acti9-ic60n-2p-32a-b-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F03232/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9F03232?","answer":"36 kA Icu at 12–133 V AC, 20 kA Icu at 220–240 V AC, 10 kA Icu at 380–415 V AC, and 6 kA Icu at 440 V AC, all per EN/IEC 60947-2. It also carries a 10 kA Icn at 400 V AC per EN/IEC 60898-1."},{"question":"What is the closest alternative to the A9F03232 in the same family?","answer":"Within the Acti9 iC60N range, the same physical footprint and terminal layout is shared across all current ratings and pole configurations. The deciding factor is the rated current (32 A) and curve B — a 40 A or curve C variant would be a different order code but mechanically interchangeable."},{"question":"Where can I buy the A9F03232 and how is it quoted?","answer":"This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock figures are published here."},{"question":"What compliance documentation does Schneider provide for the A9F03232?","answer":"The part is certified to EN/IEC 60947-2 and EN/IEC 60898-1. It carries tropicalisation class 2 per IEC 60068-1. RoHS and REACH declarations are standard for the Acti9 range; specific declaration documents are available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F03232","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F03232 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}