{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F03302","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F03302","canonicalUrl":"https://aoctrl.com/schneider/A9F03302","factsUrl":"https://aoctrl.com/api/mcp/products/A9F03302","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, miniature circuit breaker, 3P, 2 A, curve B, 50 kA breaking capacity at 240 V AC, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F03302 is a 3-pole Acti9 iC60N miniature circuit breaker rated at 2 A with a B-curve trip characteristic. This dual-standard certification (60947-2 for industrial and 60898-1 for residential/commercial) gives flexibility in panel design across both domains. The 2 A rating and B-curve (magnetic trip at 4 x In +/- 20%) suit circuits with resistive or lightly inductive loads where nuisance tripping from inrush is a concern — think lighting strings, control transformers, or small power supplies in a sub-distribution board. The 54 mm width across 3 poles fits 6 modules of 9 mm pitch — standard for a 3-pole MCB in a distribution board. Depth is 78.5 mm, height 91 mm. The toggle control and trip indicator give clear local status. Overvoltage category IV and pollution degree 3 ratings mean the breaker is rated for the highest surge exposure at the service entrance and can tolerate conductive dust and humidity up to 95% at 55 °C — a solid fit for industrial panels near the main incomer.","metaTitle":"Schneider Electric A9F03302 Acti9 iC60N MCB, 2 A, Curve B, 3","metaDescription":"Schneider Electric A9F03302 Acti9 iC60N miniature circuit breaker, 2 A rated current, curve B, 3-pole, 50 kA breaking capacity at 240 V AC. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"2 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"50 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1acb3f98dfd7b86454620ce7725f64ce.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F03302/miniature-circuit-breaker-mcb-acti9-ic60n-3p-2a-b-curve-6000a-iec-608981-50ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F03302/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9F03302 and how do I get a price?","answer":"The A9F03302 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is A9F03302's listed depth?","answer":"The depth is 78.5 mm."},{"question":"What range does A9F03302 belong to?","answer":"It belongs to the Schneider Electric Acti9 range, specifically the iC60 series."},{"question":"What compliance documentation does this brand provide for A9F03302?","answer":"The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1. Tropicalisation class 2 per IEC 60068-1 is confirmed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F03302","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F03302 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}