{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F03416","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F03416","canonicalUrl":"https://aoctrl.com/schneider/A9F03416","factsUrl":"https://aoctrl.com/api/mcp/products/A9F03416","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, A9F03416, miniature circuit breaker, 16 A, 4 poles, B-curve, 36 kA Icu at 12-133 V AC, thermal-magnetic trip, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F03416 is an Acti9 iC60N miniature circuit breaker rated 16 A with four protected poles and a B-curve magnetic trip threshold of 4 x In ±20 %. The 4-pole body (91 mm high, 78.5 mm deep) fits most distribution boards without crowding the cover. Strip length is 14 mm. IP20 finger-safe terminals are standard for enclosed panel use; no washdown rating here, so keep it behind the panel door. The Acti9 iC60N family is a broad, widely stocked line; the A9F03416 is a standard catalogue variant (16 A, 4P, B-curve).","metaTitle":"A9F03416 Acti9 iC60N MCB, 16 A, 4P, B-Curve, 36 kA","metaDescription":"Schneider Electric A9F03416 Acti9 iC60N miniature circuit breaker, 16 A rated, 4 poles, B-curve, 36 kA breaking capacity at 12-133 V AC. Complies with EN/IEC 60947-2 and 60898-1. S","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"16 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e7eb319cae1d417c98fe51c36a82f1d6.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F03416/miniature-circuit-breaker-mcb-acti9-ic60n-4p-16a-b-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F03416/alternatives.json"},"ai":{"faq":[{"question":"What standards does the A9F03416 comply with?","answer":"It is certified to both EN/IEC 60947-2 (industrial application) and EN/IEC 60898-1 (household and similar installation), giving dual coverage for commercial and light-industrial distribution boards."},{"question":"What is the breaking capacity of the A9F03416 at different voltages?","answer":"At 12-133 V AC the Icu is 36 kA; at 220-240 V AC it is 20 kA; at 380-415 V AC it is 10 kA; at 440 V AC it is 6 kA. The IEC 60898-1 Icn at 400 V AC is 6 kA."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F03416","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F03416 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}