{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F03610","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F03610","canonicalUrl":"https://aoctrl.com/schneider/A9F03610","factsUrl":"https://aoctrl.com/api/mcp/products/A9F03610","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, A9F03610, miniature circuit breaker, 1P+N, 10 A, B-curve, 36 kA breaking capacity at 12-60 VAC, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F03610 is an Acti9 iC60N miniature circuit breaker — 1P+N, 10 A rated, B-curve, thermal-magnetic trip. It's a current-production distribution breaker (lifecycle stage: current) built for DIN-rail panels where you need a switched neutral and a single protected pole. This breaker carries a 36 kA Icu at 12-60 V AC (EN/IEC 60947-2), 20 kA at 100-133 V, and 10 kA at 220-240 V. Under the residential-standard EN/IEC 60898-1 it's rated 6000 A Icn at 230 V. The dual-standard rating (60947-2 for industrial, 60898-1 for domestic) gives you flexibility in specification: you can use it in a distribution board or an industrial sub-panel. ## Trip curve and coordination B-curve means magnetic trip at 4 x In (40 A, +/-20%). For motor or drive circuits you'd typically step to C or D curve, but for distribution duty this holds selectivity well with upstream C-curve breakers. The thermal-magnetic trip unit gives you inverse-time overload protection (thermal) plus instantaneous short-circuit (magnetic). Height is 91 mm, depth 78.5 mm — check your gland plate clearance if you're fitting a deep enclosure. Terminals accept 1-25 mm² rigid or 1-16 mm² flexible, double-terminal top and bottom for daisy-chaining. IP20 finger-safe, pollution degree 3 (conductive pollution environment — typical for industrial panels not sealed from the floor).","metaTitle":"Schneider Electric A9F03610 Acti9 iC60N MCB, 10 A, 1P+N, B C","metaDescription":"Schneider Electric A9F03610 Acti9 iC60N miniature circuit breaker, 10 A rated, 1P+N, B-curve, 36 kA breaking capacity at 12-60 VAC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"10 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b13cd69ba43a30a51e4c31170f3b630f.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F03610/miniature-circuit-breaker-mcb-acti9-ic60n-1p+n-10a-b-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F03610/alternatives.json"},"ai":{"faq":[{"question":"Who supplies A9F03610 and how is it quoted for volume purchases?","answer":"We source the A9F03610 through our independent distribution network and quote it to order against an RFQ. Availability and current pricing are confirmed at quote time — send the quantity and target delivery window."},{"question":"What is the closest pin-compatible alternative to A9F03610 in this component family?","answer":"Within the Acti9 iC60N family, the closest alternative would be a different current rating or curve code — same 1P+N form factor, same DIN-rail footprint, same terminal layout. For example, an A9F03610 swaps to a C-curve (A9F03620) or a 16 A B-curve (A9F03616) without changing the panel layout. No other manufacturer's breaker is pin-compatible; the iC60N terminal spacing and neutral position are proprietary to Schneider."},{"question":"What compliance documentation does this brand provide for A9F03610?","answer":"The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1. It carries IP20 protection, pollution degree 3, overvoltage category IV, and tropicalisation class 2 per IEC 60068-1. Isolation suitability is confirmed under both standards. Standard documentation includes the declaration of conformity and the product datasheet; specific RoHS/REACH declarations are available from Schneider on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F03610","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F03610 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}