{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F03706","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F03706","canonicalUrl":"https://aoctrl.com/schneider/A9F03706","factsUrl":"https://aoctrl.com/api/mcp/products/A9F03706","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60, miniature circuit breaker, 3P+N, 6 A, Curve B, 36 kA Icu, DIN rail mount, white.","salesMarkdown":"The Schneider Electric A9F03706 is a 3P+N miniature circuit breaker from the Acti9 iC60 range, rated at 6 A with a B-curve tripping characteristic. It's a thermal-magnetic MCB for distribution boards, certified to both EN/IEC 60898-1 and EN/IEC 60947-2, so it covers residential and industrial coordination requirements. The 36 kA Icu at 12–133 V AC gives you serious fault-clearing headroom on the low-voltage side of a transformer—useful when the service entrance feeds a sub-distribution board with high prospective fault current. Breaking capacity drops with voltage: 36 kA Icu at 12–133 V AC, 20 kA at 220–240 V, 10 kA at 380–415 V, and 6 kA at 440 V. The Icn rating under EN/IEC 60898-1 is 6000 A at 400 V AC. For a 6 A MCB, that's more than enough for most final circuits, but the 10 kA at 400 V matters if you're coordinating with an upstream device in a panel with limited through-fault energy. Snaps onto a DIN rail, 72 mm wide (8 x 9 mm pitches), 91 mm tall, 78.5 mm deep. IP20 finger-safe front. Double terminals top and bottom accept 1–25 mm² rigid or 1–16 mm² flexible; strip 14 mm, torque to 2 N.m. Neutral is on the left, fixed position. The toggle switch gives a clear trip-indicator flag—no guessing whether it's off or tripped.","metaTitle":"Schneider Electric A9F03706 Acti9 iC60 MCB, 6 A, 3P+N, Curve","metaDescription":"Schneider Electric A9F03706 Acti9 iC60 miniature circuit breaker, 6 A rated, 3P+N, Curve B, 36 kA breaking capacity. Sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"6 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aa3db1b9d85c4acd20352458e012661a.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F03706/miniature-circuit-breaker-mcb-acti9-ic60n-3p+n-6a-b-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F03706/alternatives.json"},"ai":{"faq":[{"question":"What is A9F03706's listed depth?","answer":"The listed depth is 78.5 mm."},{"question":"What is A9F03706's listed range?","answer":"It belongs to the Acti9 range, specifically the Acti9 iC60 series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F03706","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F03706 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}