{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F04263","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F04263","canonicalUrl":"https://aoctrl.com/schneider/A9F04263","factsUrl":"https://aoctrl.com/api/mcp/products/A9F04263","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, miniature circuit-breaker, A9F04263, 63 A, C curve, 2P, 36 mm width, DIN rail.","salesMarkdown":"The Schneider Electric A9F04263 is an Acti9 iC60N miniature circuit-breaker rated 63 A with a C curve, 2 poles, and a 36 mm width for DIN-rail mounting. The 36 kA Icu at 12–133 V AC and 20 kA Icu at 220–240 V AC (per EN/IEC 60947-2) give this breaker headroom for high-fault industrial panels where the upstream transformer can deliver substantial short-circuit current. At 380–415 V AC the Icu drops to 10 kA, and at 440 V AC to 6 kA — still adequate for most European 400 V distribution boards. The 10 kA Icn at 400 V AC under EN/IEC 60898-1 covers the domestic and light commercial rating. The double terminals accept 1–35 mm² rigid or 1–25 mm² flexible on both top and bottom, with a 3.5 N·m tightening torque and 14 mm strip length. Overvoltage category IV suits it for main incoming panels, not just sub-distribution.","metaTitle":"Schneider Electric A9F04263 Acti9 iC60N MCB, 63 A, C Curve,","metaDescription":"Schneider Electric A9F04263 Acti9 iC60N miniature circuit breaker, 63 A rated current, C curve, 2 poles, 36 mm wide, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"63 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/035cf42cbfa8c252af712041f0c6ac32.pdf","sourceUrl":"https://www.se.com/il/en/product/A9F04263/miniature-circuit-breaker-mcb-acti9-ic60n-2p-63a-c-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F04263/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9F04263?","answer":"Submit an RFQ through this listing. Pricing and availability are confirmed at quote time through our independent distribution network — we source to order, so the quote reflects current market conditions."},{"question":"What is A9F04263's listed depth?","answer":"The A9F04263 has a depth of 78.5 mm, which fits standard DIN-rail enclosures with a 100 mm or deeper back box."},{"question":"What compliance documentation does this brand provide for A9F04263?","answer":"The A9F04263 is certified to EN/IEC 60947-2 and EN/IEC 60898-1, with tropicalisation class 2 per IEC 60068-1. Standard Schneider Electric documentation includes the declaration of conformity and test reports for these standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F04263","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F04263 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}