{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F04301","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F04301","canonicalUrl":"https://aoctrl.com/schneider/A9F04301","factsUrl":"https://aoctrl.com/api/mcp/products/A9F04301","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60 miniature circuit-breaker, A9F04301, 1 A rated current, C curve, 3 poles, 50 kA Icu at 415 V AC, DIN rail mount, white.","salesMarkdown":"The A9F04301 is a Schneider Electric Acti9 iC60 miniature circuit-breaker rated at 1 A with a C curve, three poles, and a breaking capacity of 50 kA Icu at 415 V AC. It's a thermal-magnetic trip unit designed for distribution circuits on DIN rail, covering both AC and DC networks at 50/60 Hz. The 1 A rating with C curve (magnetic trip at 8 x In ±20%) means this breaker protects small loads like control transformers or signal circuits where inrush is moderate — not motor feeders. The 10 kA Icn at 400 V (per EN/IEC 60898-1) is the domestic/commercial rating — the higher Icu figure is the industrial one that matters for distribution boards with large upstream transformers. The IP20 finger-safe terminals are standard for enclosed gear; no washdown rating here. Snaps onto DIN rail, 54 mm wide (6 x 9 mm pitches), 91 mm tall, 78.5 mm deep. Double terminals top and bottom accept 1–25 mm² rigid or 1–16 mm² flexible — strip 14 mm, torque to 2 N.m. The toggle handle and trip indicator give local status; a separate earth-leakage block can be added alongside.","metaTitle":"A9F04301 Acti9 iC60 Miniature Circuit-Breaker, 1 A, C Curve,","metaDescription":"A9F04301 Acti9 iC60 miniature circuit-breaker, 1 A rated current, C curve, 3 poles, 50 kA Icu at 415 V AC, DIN rail mount, current lifecycle. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"1 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"50 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a4652a677b8327aacb31900f17530218.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F04301/miniature-circuit-breaker-mcb-acti9-ic60n-3p-1a-c-curve-6000a-iec-608981-50ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F04301/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9F04301 and how do I get a price?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for current pricing and availability."},{"question":"What is A9F04301's breaking capacity at 415 V AC?","answer":"It carries 50 kA Icu at 380–415 V AC per EN/IEC 60947-2, and 10 kA Icn at 400 V per EN/IEC 60898-1."},{"question":"What compliance standards does A9F04301 meet?","answer":"It conforms to EN/IEC 60947-2 and EN/IEC 60898-1, with tropicalisation class 2 per IEC 60068-1 and suitability for isolation per both standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F04301","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F04301 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}