{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F04610","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F04610","canonicalUrl":"https://aoctrl.com/schneider/A9F04610","factsUrl":"https://aoctrl.com/api/mcp/products/A9F04610","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, A9F04610, miniature circuit breaker, 10 A, C-curve, 1P+N, 36 kA breaking capacity at 12-60 V AC, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F04610 is an Acti9 iC60N miniature circuit breaker (MCB) rated 10 A with a C-curve magnetic trip characteristic (8 x In +/- 20 %), in a 1P+N pole configuration. The 1P+N format protects one phase and switches the neutral without protecting it, common in single-phase final distribution circuits. Breaking capacity is the key fit parameter here: 36 kA Icu at 12-60 V AC, 20 kA at 100-133 V AC, and 10 kA at 220-240 V AC per EN/IEC 60947-2. Under the domestic-standard EN/IEC 60898-1 it carries 6000 A Icn at 230 V AC. The dual rating lets you specify it under either standard depending on the local wiring code. Thermal-magnetic trip unit technology gives two-stage protection: the thermal bimetal handles sustained overloads (e.g., a stalled fan motor drawing 13 A on a 10 A circuit), while the magnetic coil clears short-circuits instantly. The 8 x In magnetic threshold (80 A nominal) is typical for C-curve — high enough to avoid nuisance tripping on capacitor inrush or motor starting, low enough to clear a bolted fault. Mounts on DIN rail and occupies 4 x 9 mm pitches (36 mm wide), 91 mm tall, 78.5 mm deep — standard single-module width for a 1P+N MCB. The toggle control with trip indicator gives local visual status — white housing with a red flag visible when tripped. Neutral position is left; suitable for isolation per both EN/IEC 60898-1 and EN/IEC 60947-2, meaning you can safely lock it off for downstream work. Earth-leakage protection requires a separate block (Vigi iC60), not integrated.","metaTitle":"Schneider Electric A9F04610 Acti9 iC60N MCB, 10 A, C-Curve,","metaDescription":"Schneider Electric A9F04610 Acti9 iC60N miniature circuit breaker, 10 A rated, C-curve, 1P+N, 36 kA breaking capacity at 12-60 V AC. DIN rail mount, dual EN/IEC 60947-2 and 60898-1","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"10 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/92a44840f80125e693dfff2ad12c3095.pdf","sourceUrl":"https://www.se.com/nl/en/product/A9F04610/miniature-circuit-breaker-mcb-acti9-ic60n-1p+n-10a-c-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F04610/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9F04610 at 240 V AC?","answer":"10 kA Icu at 220-240 V AC per EN/IEC 60947-2, and 6000 A Icn at 230 V AC per EN/IEC 60898-1."},{"question":"What compliance documentation does Schneider provide for A9F04610?","answer":"The A9F04610 is certified to EN/IEC 60947-2 and EN/IEC 60898-1, with pollution degree 3, overvoltage category IV, and tropicalisation class 2 per IEC 60068-1. Schneider typically provides CE, UKCA, and EAC declarations for the Acti9 range; specific documentation is available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F04610","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F04610 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}