{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F04632","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F04632","canonicalUrl":"https://aoctrl.com/schneider/A9F04632","factsUrl":"https://aoctrl.com/api/mcp/products/A9F04632","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N miniature circuit breaker, A9F04632, 32 A rated current, 1P+N, C-curve, 36 kA breaking capacity, DIN-rail mount.","salesMarkdown":"The Schneider Electric A9F04632 is a 32 A miniature circuit breaker from the Acti9 iC60N series, configured as 1P+N with a C-curve trip characteristic. It protects a single pole and switches the neutral, with the neutral on the left side of the unit. Rated 32 A at 50/60 Hz, this MCB is sized for general-purpose distribution circuits feeding lighting, socket outlets, and small loads. Breaking capacity is 36 kA Icu at 12…60 V AC, 20 kA at 100…133 V AC, and 10 kA at 220…240 V AC per EN/IEC 60947-2. For domestic-style installations it carries a 6000 A Icn at 230 V per EN/IEC 60898-1. That dual-rated standard coverage (60947-2 for industrial panels, 60898-1 for residential/commercial boards) gives flexibility in specifying the same part across both worlds. At 36 mm wide (4 x 9 mm pitches) and 91 mm tall, it occupies a single modular slot plus neutral space in a distribution board. Terminals accept 1…35 mm² rigid or 1…25 mm² flexible wire, with a strip length of 14 mm and tightening torque of 3.5 N·m. The double-terminal design (top and bottom) allows looping through for daisy-chaining downstream loads without a separate junction. IP20 finger-safe protection suits enclosed panel mounting. This is a widely specified MCB for European and IEC-based distribution boards. Overvoltage category IV rating means it is suitable for installation at the origin of the installation (utility-side interface).","metaTitle":"Schneider Electric A9F04632 Acti9 iC60N MCB, 32 A, 1P+N, C-C","metaDescription":"Schneider Electric A9F04632 Acti9 iC60N miniature circuit breaker, 32 A, 1P+N, C-curve, 36 kA breaking capacity. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"32 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/058b546293e55a2d9c0e9d0a56294b63.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F04632/miniature-circuit-breaker-mcb-acti9-ic60n-1p+n-32a-c-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F04632/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9F04632?","answer":"The A9F04632 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does this brand provide for A9F04632?","answer":"Schneider Electric provides certification to EN/IEC 60947-2 and EN/IEC 60898-1, with suitability for isolation confirmed under both standards. The MCB also carries overvoltage category IV and tropicalisation class 2 ratings."},{"question":"What is A9F04632's listed depth?","answer":"The A9F04632 has a depth of 78.5 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F04632","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F04632 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}