{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F04640","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F04640","canonicalUrl":"https://aoctrl.com/schneider/A9F04640","factsUrl":"https://aoctrl.com/api/mcp/products/A9F04640","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, A9F04640, 1P+N miniature circuit breaker, 40 A, C-curve, 36 kA breaking capacity at 12-60 V AC, thermal-magnetic trip, DIN rail mount.","salesMarkdown":"The A9F04640 is a 40 A, C-curve miniature circuit breaker from the Schneider Acti9 iC60N family, 1P+N. Magnetic tripping at 8 x In ±20%. Breaking capacity is where this breaker earns its keep: 36 kA Icu at 12-60 V AC, 20 kA at 100-133 V AC, and 10 kA at 220-240 V AC per EN/IEC 60947-2. For residential-style service at 230 V, it also carries a 6 kA Icn rating per EN/IEC 60898-1 — so it's dual-rated for both industrial (60947-2) and domestic (60898-1) applications. That 78.5 mm depth is worth checking if you're fitting it into a shallow enclosure — it's deeper than some compact MCBs, so leave room for wiring and the toggle throw. If you're putting this in a washdown area, it needs an enclosure. The trip indicator gives a visual flag on the toggle — handy for a maintenance tech walking the line to spot which breaker tripped without poking at each one. Current-production part. The Acti9 iC60N line is Schneider's standard distribution MCB, widely stocked and specified globally.","metaTitle":"A9F04640 Acti9 iC60N MCB, 40 A, C-Curve, 1P+N, 36 kA","metaDescription":"Schneider Electric A9F04640 Acti9 iC60N miniature circuit breaker, 40 A, C-curve, 1P+N, 36 kA breaking capacity at 12-60 V AC. Dual-rated to EN/IEC 60947-2 and 60898-1. Available t","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"40 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cc84a7892b60c06bedfca5a8d6ffe339.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F04640/miniature-circuit-breaker-mcb-acti9-ic60n-1p+n-40a-c-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F04640/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does Schneider provide for the A9F04640?","answer":"The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1, carries IP20 protection per IEC 60529, and meets tropicalisation class 2 per IEC 60068-1. Standard Schneider documentation includes these declarations — request RoHS/REACH compliance statements with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F04640","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F04640 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}