{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F04704","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F04704","canonicalUrl":"https://aoctrl.com/schneider/A9F04704","factsUrl":"https://aoctrl.com/api/mcp/products/A9F04704","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N miniature circuit-breaker, A9F04704, 4 A rated, C-curve, 3P+N, 50 kA Icu at 415 V AC, 6 kA Icn, thermal-magnetic trip, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F04704 is an Acti9 iC60N miniature circuit-breaker rated 4 A with a C-curve, 3P+N poles, and a thermal-magnetic trip unit. The 50 kA Icu at 415 V AC (EN/IEC 60947-2) and 6 kA Icn (EN/IEC 60898-1) breaking capacities mean it handles high fault currents in commercial and industrial panels — the Icu rating governs the maximum short-circuit it can interrupt without damage, while the Icn rating covers the standard domestic/commercial duty cycle. The 72 mm width (8 x 9 mm pitches) and 78.5 mm depth fit standard distribution boards. Double terminals accept 1–25 mm² rigid or 1–16 mm² flexible cable; strip length 14 mm, tightening torque 2 N.m. IP20 finger-safe terminals. Neutral is on the left. The toggle control and trip indicator provide local status. Separate earth-leakage protection block can be added alongside. Rated for isolation (EN/IEC 60898-1 and 60947-2). Overvoltage category IV, pollution degree 3. Electrical durability 10,000 cycles, mechanical 20,000 cycles. Tropicalisation class 2 (IEC 60068-1). Limitation class 3. Operating frequency 50/60 Hz. Ambient humidity 95% at 55 °C.","metaTitle":"A9F04704 Acti9 iC60N MCB, 4 A C-curve 3P+N, 50 kA Icu","metaDescription":"Schneider Electric A9F04704 Acti9 iC60N miniature circuit-breaker, 4 A rated, C-curve, 3P+N, 50 kA Icu at 415 V AC, 6 kA Icn. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"4 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"50 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4a5cdc98319b49ca091761b367544503.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F04704/miniature-circuit-breaker-mcb-acti9-ic60n-3p+n-4a-c-curve-6000a-iec-608981-50ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F04704/alternatives.json"},"ai":{"faq":[{"question":"What is A9F04704's listed depth?","answer":"The A9F04704 has a depth of 78.5 mm."},{"question":"What is A9F04704's listed range?","answer":"The A9F04704 belongs to the Acti9 range."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F04704","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F04704 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}