{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F04713","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F04713","canonicalUrl":"https://aoctrl.com/schneider/A9F04713","factsUrl":"https://aoctrl.com/api/mcp/products/A9F04713","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60, miniature circuit-breaker, A9F04713, 13 A, C curve, 3P+N, 36 kA breaking capacity.","salesMarkdown":"The Schneider Electric A9F04713 is an Acti9 iC60 miniature circuit-breaker (MCB) rated 13 A with a C curve, thermal-magnetic trip, and 3 protected poles plus neutral (3P+N). Snaps onto a DIN rail — standard 9 mm pitch, 8 modules wide (72 mm). Height is 91 mm, depth 78.5 mm. That's a compact footprint for a 3P+N breaker; you'll fit it into a 4-row enclosure without crowding. Neutral is on the left. IP20 rated — fine inside a panel, not for wet locations. Overvoltage category IV means it's rated for installation at the service entrance, not just downstream subpanels. Dual-certified to EN/IEC 60898-1 and EN/IEC 60947-2. Suitability for isolation is confirmed under both standards — you can safely use it as a disconnecting means.","metaTitle":"A9F04713 Acti9 iC60 MCB, 13 A, C curve, 3P+N, 36 kA","metaDescription":"Schneider Electric A9F04713 Acti9 iC60 MCB, 13 A rated, C curve, 3P+N, breaking capacity 36 kA at 133 V AC. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"13 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/915ab879e309dcddd49a0ebc0043d0df.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F04713/miniature-circuit-breaker-mcb-acti9-ic60n-3p+n-13a-c-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F04713/alternatives.json"},"ai":{"faq":[{"question":"What is A9F04713's breaking capacity?","answer":"Breaking capacity is 36 kA Icu at 12–133 V AC, 20 kA at 220–240 V AC, 10 kA at 380–415 V AC, 6 kA at 440 V AC, and 6000 A Icn at 400 V per EN/IEC 60898-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F04713","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F04713 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}