{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F04720","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F04720","canonicalUrl":"https://aoctrl.com/schneider/A9F04720","factsUrl":"https://aoctrl.com/api/mcp/products/A9F04720","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, miniature circuit breaker, 20 A, 3P+N, C-curve, breaking capacity 36 kA Icu at 12-133 V AC, DIN rail mount.","salesMarkdown":"## Acti9 iC60N — 20 A, 3P+N, C-Curve MCB The Schneider Electric A9F04720 is a 20 A, 3P+N miniature circuit breaker from the Acti9 iC60N series, with a C-curve trip characteristic. Rated for both AC and DC networks at 50/60 Hz, this MCB carries a breaking capacity of 36 kA Icu at 12-133 V AC, 20 kA Icu at 220-240 V AC, 10 kA Icu at 380-415 V AC, and 6 kA Icu at 440 V AC, per EN/IEC 60947-2. The Icn rating per EN/IEC 60898-1 is 6000 A at 400 V AC. The C-curve means magnetic tripping occurs at 8 x In ±20%, suitable for circuits with moderate inrush currents like lighting or small motor loads. The 3P+N configuration protects three phases with a switched neutral on the left side. Overvoltage category IV and pollution degree 3 ratings confirm it is suitable for main distribution panels in industrial environments. The IP20 finger-safe enclosure is standard for panel-mount breakers; no washdown rating. ## Panel Integration Occupies 8 x 9 mm pitches (72 mm) on the DIN rail. The 78.5 mm depth leaves clearance for standard enclosure depths. Double terminals top and bottom accept 1-25 mm² rigid or 1-16 mm² flexible conductors.","metaTitle":"Schneider Electric A9F04720 Acti9 iC60N MCB, 20 A, 3P+N, C-C","metaDescription":"Schneider Electric A9F04720 Acti9 iC60N miniature circuit breaker, 20 A rated, 3P+N, C-curve, 36 kA breaking capacity. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"20 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/db64205743007fa7d6df84362606e365.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F04720/miniature-circuit-breaker-mcb-acti9-ic60n-3p+n-20a-c-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F04720/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the A9F04720?","answer":"The A9F04720 is sourced and quoted to order against an RFQ through independent distribution. Availability and pricing are confirmed at quote time."},{"question":"What is the breaking capacity of the A9F04720?","answer":"The breaking capacity is 36 kA Icu at 12-133 V AC, 20 kA Icu at 220-240 V AC, 10 kA Icu at 380-415 V AC, and 6 kA Icu at 440 V AC per EN/IEC 60947-2. The Icn rating per EN/IEC 60898-1 is 6000 A at 400 V AC."},{"question":"What standards does the A9F04720 comply with?","answer":"It complies with EN/IEC 60947-2 and EN/IEC 60898-1, and is suitable for isolation per both standards. It also conforms to IEC 60068-1 for tropicalisation (class 2) and IEC 60529 for IP20 protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F04720","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F04720 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}