{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F04725","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F04725","canonicalUrl":"https://aoctrl.com/schneider/A9F04725","factsUrl":"https://aoctrl.com/api/mcp/products/A9F04725","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, A9F04725, miniature circuit breaker, 25 A, C curve, 3P+N, 36 kA Icu.","salesMarkdown":"The Schneider Electric A9F04725 is an Acti9 iC60N miniature circuit breaker rated for 25 A with a C curve, configured as 3P+N. It carries a 36 kA Icu breaking capacity at 12…133 V AC and 20 kA at 220…240 V AC, dual-certified to EN/IEC 60947-2 and EN/IEC 60898-1. Mounts on DIN rail (9 mm pitch, 8 pitches wide — 72 mm width). The 3P+N configuration places the neutral on the left, with a toggle control and a trip indicator for local signalling. IP20 rated for enclosure use. Lifecycle stage is current production. The A9F04725 is an active catalog item within the Acti9 range, widely specified in European and IEC-based distribution boards.","metaTitle":"Schneider Electric A9F04725 Acti9 iC60N MCB, 25 A, C Curve,","metaDescription":"Schneider Electric A9F04725 Acti9 iC60N miniature circuit breaker, 25 A rated current, C curve, 3P+N poles, 36 kA Icu breaking capacity. Dual certified to EN/IEC 60947-2 and 60898-","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"25 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c720186615783109b7434b1bc6f74ab6.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F04725/miniature-circuit-breaker-mcb-acti9-ic60n-3p+n-25a-c-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F04725/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9F04725 at 400 V?","answer":"At 400 V AC 50/60 Hz, the A9F04725 is rated 10 kA Icu per EN/IEC 60947-2 and 6000 A Icn per EN/IEC 60898-1."},{"question":"What compliance documentation does A9F04725 carry?","answer":"The A9F04725 is dual-certified to EN/IEC 60947-2 and EN/IEC 60898-1, with tropicalisation class 2 per IEC 60068-1 and suitability for isolation per both standards. Pollution degree 3 and overvoltage category IV are specified. Earth-leakage protection requires a separate Vigi block."},{"question":"Where can I buy A9F04725 and how is it quoted?","answer":"The A9F04725 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock or price figures are published here."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F04725","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F04725 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}