{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F04763","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F04763","canonicalUrl":"https://aoctrl.com/schneider/A9F04763","factsUrl":"https://aoctrl.com/api/mcp/products/A9F04763","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60, miniature circuit breaker, 63 A, 3P+N, C-curve, 36 kA breaking capacity at 133 V AC, DIN rail mount.","salesMarkdown":"The A9F04763 is a 63 A, 3P+N miniature circuit breaker from the Schneider Acti9 iC60 series, with a C-curve trip characteristic (magnetic trip at 8 x In ±20 %). The breaking capacity tells the real story: 36 kA Icu at 12–133 V AC, 20 kA at 220–240 V, 10 kA at 380–415 V, and 6 kA at 440 V AC per EN/IEC 60947-2. For IEC 60898-1 applications it's rated 6000 A Icn at 400 V. That means it can clear high fault currents on the low-voltage side of a distribution transformer without welding contacts — critical for a mill feeder or sub-distribution panel where available fault current can hit those levels. Snaps onto a DIN rail (9 mm pitch, 8 pitches wide — 72 mm width, 91 mm height, 78.5 mm depth). The double terminals accept 1–35 mm² rigid or 1–25 mm² flexible; tightening torque is 3.5 N·m. IP20 rated, so it's for inside a panel — not washdown. The toggle provides local on/off with a trip indicator. Neutral on the left, 3 protected poles on the right. Earth-leakage protection requires a separate block (not built in). Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household/similar) — so it fits both a factory distribution board and a commercial sub-panel. Suitability for isolation is confirmed under both standards. Pollution degree 3, overvoltage category IV, tropicalisation class 2 per IEC 60068-1. 10,000 electrical cycles, 20,000 mechanical cycles.","metaTitle":"Schneider Electric A9F04763 Acti9 iC60 MCB, 63 A, 3P+N, C-Cu","metaDescription":"Schneider Electric A9F04763 Acti9 iC60 miniature circuit breaker, 63 A, 3P+N, C-curve, 36 kA breaking capacity at 133 V AC, DIN rail. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"63 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/11295ab3d6c29816c840253bf7193648.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F04763/miniature-circuit-breaker-mcb-acti9-ic60n-3p+n-63a-c-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F04763/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9F04763 and how do I get a price?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at that time."},{"question":"What is the A9F04763's breaking capacity at 400 V?","answer":"Under EN/IEC 60898-1 it is rated 6000 A Icn at 400 V AC; under EN/IEC 60947-2 it is rated 10 kA Icu at 380–415 V AC and 6 kA Icu at 440 V AC."},{"question":"What compliance documentation does Schneider provide for A9F04763?","answer":"The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1, with tropicalisation class 2 per IEC 60068-1. For RoHS, REACH, and UL documentation, check the manufacturer's product compliance portal or request a certificate of conformity with your order."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F04763","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F04763 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}