{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F05101","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F05101","canonicalUrl":"https://aoctrl.com/schneider/A9F05101","factsUrl":"https://aoctrl.com/api/mcp/products/A9F05101","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, A9F05101, miniature circuit breaker, 1 A, D curve, 1 pole, 50 kA Icu at 240 V AC, thermal-magnetic trip, DIN rail mount.","salesMarkdown":"The 1 A rating means it protects a circuit drawing up to 1 A continuous — sized for a control transformer primary, a PLC power supply feed, or a signal loop, not a motor branch. The D curve (magnetic trip at 12× In, ±20%) means it tolerates inrush up to roughly 14.4 A before instant tripping, so it suits loads with a high starting surge like small transformers or solenoid banks. The single-pole (1P) form factor breaks only the line conductor; the neutral is switched separately or left solid. Double terminals top and bottom accept 1 to 25 mm² rigid or 1 to 16 mm² flexible, with a 14 mm strip length and 2 Nm tightening torque. The toggle actuator and trip indicator give local status without opening the panel door. IP20 finger-safe terminals suit enclosed panel use — not for wet or washdown locations. Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household / similar) — so it qualifies for both panel-level distribution and final subcircuit protection. Pollution degree 3 (conductive pollution, typical in control cabinets without climate control). Overvoltage category IV (mains-level surge withstand). Suitability for isolation marked on the device, per both standards.","metaTitle":"A9F05101 Acti9 iC60N 1A D Curve MCB, 50 kA Icu","metaDescription":"Schneider Electric A9F05101 Acti9 iC60N miniature circuit breaker, 1A D curve, 1P, 50 kA Icu at 240 V AC, DIN rail mount. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"D","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"1 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"50 kA 100 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - 12...60 V DC 10 kA 100 % conforming to EN/IEC 60947-2 - 60...72 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b8ac600487e5e9fc21731b29e15929df.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F05101/miniature-circuit-breaker-mcb-acti9-ic60n-1p-1a-d-curve-6000a-iec-608981-50ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F05101/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9F05101?","answer":"Submit an RFQ against this order code. Availability and current pricing are confirmed at quote time through independent distribution channels."},{"question":"What is A9F05101's breaking capacity?","answer":"50 kA Icu at 240 V AC per EN/IEC 60947-2, and 6 kA Icn at 230 V AC per EN/IEC 60898-1. The 50 kA figure governs industrial panel SCCR; the 6 kA figure covers residential final-circuit duty."},{"question":"What is the closest alternative to A9F05101 in the Acti9 family?","answer":"The same iC60N platform with a different curve or current rating. A B-curve unit (A9F05101's sibling with curve B) would trip sooner on inrush — not a pin-compatible drop-in for a D-curve spec. Stick with the D curve for transformer or solenoid loads."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F05101","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F05101 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}