{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F05150","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F05150","canonicalUrl":"https://aoctrl.com/schneider/A9F05150","factsUrl":"https://aoctrl.com/api/mcp/products/A9F05150","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, miniature circuit-breaker, 1P, 50 A, D curve, 36 kA Icu at 12-60 V AC, DIN rail mount, white.","salesMarkdown":"The Schneider Electric A9F05150 is a 1-pole Acti9 iC60N miniature circuit-breaker rated at 50 A with a D tripping curve. It protects downstream distribution circuits against overloads and short-circuits, and it does so under two standards at once — EN/IEC 60898-1 for household-type installations and EN/IEC 60947-2 for industrial panel duty. That dual certification means the same part can serve a building distribution board or an industrial control cabinet without requalifying the BOM line. If you are replacing a legacy thermal-magnetic breaker on a conveyor drive or a pump panel, this curve is the one that meets it where it is without gutting the coordination study. The A9F05150 has 36 kA Icu at 12-60 V AC and 10 kA Icu at 220-240 V AC per EN/IEC 60947-2, plus 6 kA Icn at 230 V AC per EN/IEC 60898-1. On DC, it breaks 15 kA at 12-60 V DC and 10 kA at 60-72 V DC. Limitation class is 3 per EN/IEC 60898-1. Height is 91 mm, depth 78.5 mm. Terminals accept 1-35 mm² rigid or 1-25 mm² flexible copper, with a tightening torque of 3.5 N.m. The double-terminal design (top and bottom) lets you loop a feed-through busbar or daisy-chain the outgoing side without piggyback terminals. Wire stripping length is 14 mm — standard for this class, but worth confirming your ferrule length if using pre-terminated cables. ## Environmental and compliance details IP20 rated (finger-safe terminals, no washdown protection — keep it inside the enclosure). Overvoltage category IV. Insulation voltage is rated at 500 V AC.","metaTitle":"A9F05150 Acti9 iC60N MCB, 1P, 50 A, D Curve, 36 kA","metaDescription":"Schneider Electric A9F05150 Acti9 iC60N miniature circuit-breaker, 1-pole, 50 A, D curve, 36 kA Icu at 12-60 V AC. Sourced to order against RFQ. EN/IEC 60947-2 & 60898-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"D","9 Mm Pitches":"2","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"50 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - 12...60 V DC 10 kA 100 % conforming to EN/IEC 60947-2 - 60...72 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3818f56facdad14e157a0043694942cd.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F05150/miniature-circuit-breaker-mcb-acti9-ic60n-1p-50a-d-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F05150/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does Schneider provide for A9F05150?","answer":"The A9F05150 is certified to EN/IEC 60947-2 and EN/IEC 60898-1. It carries a suitability for isolation marking per both standards. Standard compliance documentation (declaration of conformity, CE marking) is available from Schneider Electric's documentation portal for the Acti9 iC60N series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F05150","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F05150 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}