{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F05163","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F05163","canonicalUrl":"https://aoctrl.com/schneider/A9F05163","factsUrl":"https://aoctrl.com/api/mcp/products/A9F05163","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60 miniature circuit-breaker, A9F05163, 63 A rated current, D curve, 1 pole, 36 kA Icu at 12-60 V AC, DIN rail mount, white.","salesMarkdown":"The Schneider Electric A9F05163 is an Acti9 iC60 miniature circuit-breaker, 1 pole, rated 63 A with a D curve, designed for distribution applications on AC or DC networks. Breaking capacity is specified under dual standards: 36 kA Icu at 12-60 V AC (EN/IEC 60947-2) and 6 kA Icn at 230 V AC (EN/IEC 60898-1). The 36 kA figure governs fault-clearing capability in industrial panels; the 6 kA Icn is the residential/commercial rating under the MCB standard. Rated insulation voltage (Ui) of 500 V AC and overvoltage category IV mean it is rated for main distribution panels, not just sub-circuits — suitable for service-entrance or branch feeder positions. Strip length 14 mm. Overall dimensions: 91 mm height, 78.5 mm depth, 18 mm width — fits standard modular enclosure cutouts.","metaTitle":"Schneider Electric A9F05163 Acti9 iC60 MCB, D Curve, 63 A, 1","metaDescription":"Schneider Electric A9F05163 Acti9 iC60 miniature circuit-breaker, 63 A, D curve, 1 pole, 36 kA breaking capacity, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"D","9 Mm Pitches":"2","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"63 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - 12...60 V DC 10 kA 100 % conforming to EN/IEC 60947-2 - 60...72 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a3a944c6b9685c7c82f65d90dd8aec8a.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F05163/miniature-circuit-breaker-mcb-acti9-ic60n-1p-63a-d-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F05163/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9F05163?","answer":"The breaking capacity is 36 kA Icu at 12-60 V AC (EN/IEC 60947-2) and 6 kA Icn at 230 V AC (EN/IEC 60898-1). For DC circuits it is 15 kA Icu at 12-60 V DC and 10 kA Icu at 60-72 V DC."},{"question":"What does the D curve mean on this breaker?","answer":"The D curve sets the magnetic trip threshold at 12 x In +/- 20%, so the breaker tolerates high inrush currents typical of motors, transformers, or welding equipment without nuisance tripping."},{"question":"How do I get current pricing and availability for A9F05163?","answer":"The part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quote."},{"question":"What compliance documentation does A9F05163 carry?","answer":"The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1, suitable for isolation per both standards, and rated IP20. It also meets tropicalisation class 2 per IEC 60068-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F05163","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F05163 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}