{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F05216","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F05216","canonicalUrl":"https://aoctrl.com/schneider/A9F05216","factsUrl":"https://aoctrl.com/api/mcp/products/A9F05216","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, miniature circuit-breaker, 16 A, D curve, 2P, 36 mm, breaking capacity 36 kA Icu at 12-133 V AC.","salesMarkdown":"The Schneider Electric A9F05216 is a 16 A, D-curve, 2-pole miniature circuit-breaker from the Acti9 iC60N series, built for distribution panels. It sits on a DIN rail, takes up 36 mm (4 x 9 mm pitches), and is rated for both AC and DC networks at 50/60 Hz. The D curve means its magnetic trip fires at 12 x In (±20%), so it handles high inrush currents typical of motor loads, transformers, or discharge lighting without nuisance tripping. For a 16 A breaker, that's around 192 A instantaneous trip threshold. Breaking capacity is the headline: 36 kA Icu at 12-133 V AC, 20 kA at 220-240 V, 10 kA at 380-415 V, and 6 kA at 440 V — all per IEC 60947-2. It also carries a 10 kA Icn at 400 V per IEC 60898-1. The 36 mm width (2-pole) fits a typical 4-module slot in a consumer unit or distribution board. Terminals accept 1-25 mm² rigid or 1-16 mm² flexible, with a double-terminal design for daisy-chaining or ring-feed. Torque to 2 N·m, strip 14 mm. Dual-certified to both IEC 60898-1 (the household/industrial MCB standard) and IEC 60947-2 (the industrial circuit-breaker standard). That dual rating gives it a wider acceptance for both residential and industrial specs. Also carries the isolation suitability mark per both standards — you can use it as a disconnector.","metaTitle":"Schneider Electric A9F05216 Acti9 iC60N MCB, 16 A, D Curve,","metaDescription":"Schneider Electric A9F05216 Acti9 iC60N miniature circuit-breaker, 16 A, D curve, 2-pole, 36 mm wide. Breaking capacity 36 kA at 12-133 V AC. Quoted to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"D","9 Mm Pitches":"4","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"16 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7220e56e37617d4fa5a73b0319192ca3.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F05216/miniature-circuit-breaker-mcb-acti9-ic60n-2p-16a-d-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F05216/alternatives.json"},"ai":{"faq":[{"question":"What is the A9F05216's breaking capacity at 400 V?","answer":"At 380-415 V AC it carries 10 kA Icu (IEC 60947-2) and a 10 kA Icn at 400 V (IEC 60898-1). At 440 V the Icu drops to 6 kA."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F05216","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F05216 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}