{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F05332","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F05332","canonicalUrl":"https://aoctrl.com/schneider/A9F05332","factsUrl":"https://aoctrl.com/api/mcp/products/A9F05332","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, miniature circuit-breaker, A9F05332, D curve, 32 A, 3P, 36 kA breaking capacity, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F05332 is an Acti9 iC60N miniature circuit-breaker (MCB) — a 3-pole, 32 A unit with a D tripping curve, designed for distribution boards and industrial control panels. ## Breaking capacity — what it clears and where Breaking capacity is the headline number for an MCB: the A9F05332 is rated 36 kA Icu at 12–133 V AC, 20 kA at 220–240 V, 10 kA at 380–415 V, and 6 kA at 440 V, all per EN/IEC 60947-2. It also carries a 10 kA Icn at 400 V per EN/IEC 60898-1. The 36 kA figure at low voltage is what you care about for high-fault utility feeds; the 10 kA at 400 V covers most European industrial distribution. Dual-certified to both the industrial (60947-2) and household (60898-1) standards, so it qualifies for either duty. Height is 91 mm, depth 78.5 mm. The double terminals top and bottom accept 1–35 mm² rigid or 1–25 mm² flexible — enough for the 32 A feed and downstream tails. Tightening torque is 3.5 Nm; strip length 14 mm. IP20 finger-safe terminals, pollution degree 3, overvoltage category IV. That's a distribution-grade MCB ready for a main panel, not a branch-only device.","metaTitle":"Schneider Electric A9F05332 Acti9 iC60N MCB, D Curve 32 A 3P","metaDescription":"Schneider Electric A9F05332 Acti9 iC60N miniature circuit-breaker. D curve, 32 A, 3-pole, 36 kA breaking capacity. EN/IEC 60947-2 & 60898-1. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"D","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"32 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a53b92991b2aaa1a5f42b9e3ec799820.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F05332/miniature-circuit-breaker-mcb-acti9-ic60n-3p-32a-d-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F05332/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9F05332?","answer":"36 kA Icu at 12–133 V AC, 20 kA at 220–240 V, 10 kA at 380–415 V, and 6 kA at 440 V per EN/IEC 60947-2; also 10 kA Icn at 400 V per EN/IEC 60898-1."},{"question":"What does the D curve mean on this MCB?","answer":"The D curve trips magnetically at 12 x In (12 x 32 A = 384 A) with a +/-20% tolerance, designed for loads with high inrush current like motors, transformers, and welding equipment."},{"question":"What is the A9F05332's DIN-rail width?","answer":"It occupies 6 modules at 9 mm pitch, so 54 mm wide. Height is 91 mm, depth 78.5 mm."},{"question":"Where can I buy the A9F05332 and what is the lead time?","answer":"Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead-time estimate."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F05332","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F05332 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}